American Standard 3770 Make Water Supply Connections, Test Installed Fitting, Service

Models: 3770

1 2
Download 2 pages 22.88 Kb
Page 2
Image 2
3 MAKE WATER SUPPLY CONNECTIONS

3 MAKE WATER SUPPLY CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE PURCHASED SEPARATELY.

Connect water supply to FAUCET SHANKS (1) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).

Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

 1TEST INSTALLED FITTINGSERVICE3 1

1

2

COUPLING NUT

3

ALIGN HANDLES FERRULE

4

TEST INSTALLED FITTING

5

SERVICE

STOP

90˚

 

 

 

WASHER

 

 

With HANDLES (1) in OFF position, turn on WATER

 

To change direction of handle rotation,

 

 

SUPPLIES (2) and check all connections for leaks.

 

 

 

 

 

proceed as follows:

 

 

 

Remove AERATOR (3).

 

Turn valve to OFF position.

 

 

 

Operate both HANDLES to flush water lines thoroughly.

 

Pull out INDEX CAP and remove

 

 

 

HANDLE SCREW.

 

 

 

Replace AERATOR (3).

 

Remove SPRING CLIP.

 

SPRING

 

 

Lift STOP WASHER, turn 90˚ and replace.

 

 

 

Replace SPRING CLIP.

 

CLIP

 

 

 

 

 

 

 

 

Replace ADAPTER, HANDLE, SCREW, and INDEX CAP.

 

 

 

AERATOR may accumulate dirt causing distorted and

 

 

 

reduced water flow. Remove AERATOR and rinse clean.

 

 

 

If spout drips, operate handles several times from OFF

 

 

 

to ON position. Do not force - handles turn only 90˚.

3

1

1

ALIGN HANDLES

Pull out INDEX CAP (1) and remove

1

2

HANDLE SCREW (2), HANDLE (3)

and ADAPTER (4).

3

Push ADAPTER (4) on VALVE STEM (5).

 

Find correct position of HANDLE (3) by

 

adjusting male teeth on ADAPTER (4) to

4

female teeth on HANDLE (3).

Replace HANDLE SCREW (2) and push

5

in INDEX CAP (1).

 

2

6 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968935 Rev . 1 . 1

Page 2
Image 2
American Standard 3770 Make Water Supply Connections, Test Installed Fitting, Service, Align Handles, Care Instructions