American Standard 4332.350.XXX installation instructions Service

Models: 4332.350.XXX

1 4
Download 4 pages 33.7 Kb
Page 3
Image 3
4 SERVICE
M968577 Rev . 1 . 1

4 SERVICE

Clogged CARTRIDGE outlets or inlets may cause reduced flow. To clean, first turn off water supply then:

Loosen and remove LEVER HANDLE (1). Loosen HANDLE SCREW (2) with 2.5mm Hex Wrench and then pull HANDLE BASE (3) off.

Unscrew ESCUTCHEON CAP (4). Unscrew the

CARTRIDGE NUT (5).

Remove CARTRIDGE (6). Clean inlets of

CARTRIDGE (6) and MANIFOLD (7).

Reassemble CARTRIDGE (6). Replace CARTRIDGE NUT (5), CAP (4) and HANDLE assembly, check flow.

1

CLEAN

5

4

7

2

6

33

5 SERVICE

If SPOUT (3) leaks at swivel point the O-RINGS (2) need to be replaced. To remove SPOUT (3):

Loosen the SPOUT SET SCREW (1) with a 3mm Hex wrench.

Rotate the SPOUT (3) side to side while pulling upward to remove SPOUT (3) from faucet body.

Replace the defective parts, grease O-RINGS then push SPOUT (3) back into position. Tighten SET SCREW (1).

Check that SPOUT (3) rotates freely and does not leak at the swivel point.

REMOVE

INSTALL

3

2

Manual background1

3mm HEX WRENCH

6 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.