ATTACH CABLE CONNECTOR

7

ATTACH CABLE CONNECTOR

 

 

 

 

 

Fig. A.

 

 

Fig. B.

 

Thread CABLE CONNECTOR (1) clockwise

 

 

 

 

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

 

 

 

 

hand tighten. Fig. A.

 

 

 

 

 

 

 

 

 

 

Your new POP-UP DRAIN installation is now complete. Fig. B.

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

Fig. B.

2

Fig. A. 1-1/4” O.D.

8 CHECK OPERATION OF POP-UP

 

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

1

closes.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

Fig. B.2

9 MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).

Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.

1/2" PIPE

1

THREAD

 

2

COUPLING

NUT

FLEXIBLE

 

SUPPLIES

 

3

3/8 O.D.

BULL-NOSE

RISERS

3/8” COMPRESSION CONNECTION

COMPRESSION NUT

FERRULE

HOTCOLD

M968843 Rev . 1 . 2