10 TEST INSTALLED FITTING

10 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks. CHECK DRAIN CONNECTIONS

Remove AERATOR (3).

4

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

1

 

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. 11 SERVICE Tighten

if necessary.

5

WASTE

OUTLET

12 CARE INSTRUCTIONS:Manual background1

Manual background 3

2

2

“P” TRAP

11 SERVICE

To change direction of handle rotation, proceed as follows:

2

1

Turn VALVE in OFF position.

Loosen HANDLE SCREW (1).

4

Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER SCREW (4) and pull off ADAPTER (3).

Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches the other flat on VALVE STEM (5).

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).

Tighten HANDLE SCREW (1).

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

90˚

3

5Manual background

FLAT

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968843 Rev . 1 . 2