10 TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3). | 4 |
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3). | 1 |
|
CHECK DRAIN CONNECTIONS
Operate
Release
if necessary.
5
WASTE
OUTLET
1
3
2
2 | “P” TRAP |
11 SERVICE
To change direction of handle rotation, proceed as follows:
2
1
Turn VALVE in OFF position.
Loosen HANDLE SCREW (1).
4
Pull HANDLE (2) off ADAPTER (3). Loosen ADAPTER SCREW (4) and pull off ADAPTER (3).
Turn ADAPTER (3) 90˚ in a way that flat in ADAPTER (3) catches the other flat on VALVE STEM (5).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
90˚
3
5
FLAT
12 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
M968843 Rev . 1 . 2
4