American Standard 4508S installation instructions Fig. A, Cold

Models: 4508S

1 7
Download 7 pages 63.88 Kb
Page 4
Image 4
2

9 INSTALL HANDLES

 

 

 

Push ADAPTER (1) on VALVE STEM (2), so that the hole of the

 

 

ADAPTER (1) without a spline is facing up. Fig. A. Tighten

 

THREAD ON

STEM SCREW (3) to secure ADAPTER (1).

 

 

 

4

TO DECK

 

 

ADAPTER

Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting

 

 

male teeth on ADAPTER (1) to female teeth in HANDLE (4).

TOP

 

Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5)

 

1

until snug against mounting surface.

 

 

Fig. A.

 

 

 

 

3

 

 

 

2

 

SPLINE END DOWN

 

5

 

 

 

10 TEST INSTALLED FITTING

 

5

 

 

 

1

With HANDLES (1) in OFF position, turn on WATER

 

SUPPLIES (2) and check all connections for leaks.

 

 

Remove AERATOR (3).

 

 

 

Operate both HANDLES (1) to flush water

 

 

 

lines thoroughly.

 

 

 

Replace AERATOR (3).

1

 

 

Manual background 3

4

11 CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (5) and fill Sink with water. Check that DRAIN STOPPER (4) makes a good seal and retains water in Sink. If STOPPER (4) does not seal properly, please refer to “Troubleshooting Guide” in these instructions.

Release POP-UP KNOB (5) down and check all drain connections and "P" trap for leaks.Manual background Tighten

if necessary.

WASTE OUTLET

2

COLD

HOT

“P” TRAP

2

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

13 SERVICE

 

 

 

HANDLE

To change direction of handle rotation,

 

 

ASSEMBLY

 

 

 

proceed as follows:

UNTHREAD

 

 

Turn valve to OFF position. Unthread HANDLE

 

 

 

 

 

BASE (1) from DECK ADAPTER (2).

1

 

 

Pull HANDLE ASSEMBLY off VALVE STEM (3).

 

 

Remove SPRING CLIP (4). Lift STOP WASHER (5),

 

 

turn 90˚ and replace. Replace SPRING CLIP (4).

 

 

 

Find correct position of HANDLE ASSEMBLY by adjusting

90˚

 

male teeth on VALVE STEM (3) to female teeth in HANDLE.

3

Thread HANDLE ASSEMBLY onto DECK ADAPTER (2)

 

5

until snug against mounting surface.

4

 

 

 

 

If spout drips, operate handles several times from

2

 

 

OFF to ON position. Do not force - handles turn

 

 

 

only 90˚.

M968672 Rev . 1 . 1

 

4

Page 4
Image 4
American Standard 4508S installation instructions Fig. A, Cold