INSTALL MIRROR/MEDICINE CABINET

Note: Cabinet can be installed either right hand or left hand by rotating cabinet180 degrees.

Install MIRROR/MEDICINE CABINET into finished opening in wall. Check for level and that cabinet frame fits flush against finished wall. Shim as required to make level. (Figure A)

￿ Drill two 1/8" dia. pilot holes into top and bottom of cabinet. Secure cabinet to framing with wood screws. (Figure B)

PILOT HOLES

Figure A

Figure B

INSTALL MOUNTING PLATES

Note: Refer to Figure A for use of TEMPLATES (A & B) or DIMENSIONS to locate the four MOUNTING PLATES (1).

To use TEMPLATES (A & B), to locate the center of each MOUNTING PLATE (1), cut the template out cutting on the dotted lines. Starting at lower left corner of cabinet frame, locate the template as illustrated. Tape into place and mark the three centers of the MOUNTING PLATE (1). Use TEMPLATE (A) for corners 1 & 3 and TEMPLATE (B) for corners 2 & 4 marking the MOUNTING PLATE (1) locations and mounting holes. Check with a level that the center to center measurements are level.

To use DIMENSIONS, to locate the center of each MOUNTING PLATE (1) start at the lower left corner of cabinet frame. Measure as indicated to locate the center of each MOUNTING PLATE (1). Mark the centers for the left side MOUNTING PLATE (1) and use the same measurements to locate the centers of the right side. Check with a level that the center to center measurements are level.

For best installation results it is recommended to secure MOUNTING PLATES (1) to reinforcements studs. No Anchors are needed. Drill small pilot holes for SCREWS (3).

For installations on drywall without reinforcement studs, use DRYWALL ANCHORS (2) and SCREWS (3) for securing

MOUNTING PLATE (1) to wall. Place #2 Phillips screwdriver or cordless screwdriver into recess of anchor. Press into drywall while turning the anchor clockwise until it is seated flush with the wall. Place MOUNTING PLATE (1) over DRYWALL ANCHOR (2) and insert SCREWS (3) with #2 Phillips screwdriver. See FIGURE B below. Secure MOUNTING PLATE (1) to wall with SCREWS (3).

For installations on tiled walls without reinforcement studs, If TILE ANCHORS (4) and SCREWS (3) are used for securing MOUNTING PLATE (5), then drill two 1/4" diameter holes a minimum of 1-1/4" deep. Insert the two TILE ANCHORS (4) flush with face of the finished wall. Secure MOUNTING PLATE (1) to wall with SCREWS (3).

1-15/16"

Figure A

2

23

 

 

 

 

 

CENTER LINE

1

 

25-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

LOWER LEFT

 

 

 

1

4

 

FINISHED

 

 

 

Figure B

 

WALL

CORNER

 

 

 

 

 

 

 

 

 

 

 

OF CABINET

 

 

 

3

 

 

 

A

1

4

 

NOTE; For best installation results use:

 

 

 

 

 

 

1-3/32"

• No Anchors, Screws (3) directly secured to

1-3/32"

 

 

 

reinforcement studs

 

 

 

 

 

 

• TILE ANCHORS (4) for tile or plaster walls

 

 

 

LEVEL

 

• DRYWALL ANCHORS (2) for dry wall

￿￿￿￿￿￿￿￿

1

1-15/16"

 

 

 

 

19-3/8"

 

 

 

Page 2
Image 2
American Standard 6771 installation instructions Install MIRROR/MEDICINE Cabinet, Install Mounting Plates