1 SWING SPOUT ASSEMBLY |
| ||
CAUTION | Turn off hot and cold water | 3 | |
supplies before beginning. | |||
|
| ||
Assemble the SPOUT (3) and tighten the | 4 | ||
SPOUT NUT (4) until snug on VALVE BODY. |
|
2 1
2 FITTING INSTALLATION
Remove LOCKNUT (1), BRASS WASHER (2), and GASKET (3) from fitting.
Place RUBBER RING (4) in recess of fitting.
Insert inlet hoses (on model 7190.132 only) and THREADED SHANK through hole of sink making certain RUBBER RING (4) is properly seated in the recess of the fitting base.
Assemble GASKET (3), BRASS WASHER (2), and LOCKNUT (1) onto the THREADED SHANK from underside of sink deck.
Tighten the LOCKNUT (1) securely.
MODEL 7190.132
RECESS
MODEL 7100. 2XX
RECESS
4
For Model 7190.132 Only
Connect the hot water supply to the left inlet hose and the cold water supply to the right inlet hose using appropriate connectors.
SHANK
3
For Model 7100.2XX Only
Connect hot or cold water supply lines to shank using sealant, appropriate connectors, and coupling nuts.
|
| 2 |
HOT |
| 1 |
FLEXIBLE | COLD | SUPPLY |
INLET HOSES |
| NUT |
3 TEST INSTALLED FAUCET
Remove AERATOR.
With handle in OFF position, turn on water supplies and check all connections for leaks.
Operate both handles to flush water lines thoroughly. Checkspout mounting and hose connections for leaks.
Turn handles into OFF position and replace AERATOR.
4 | SERVICE | 2 | 90° |
|
| ||
| To change direction of handle rotation, | 1 | |
| proceed as follows: |
|
|
| Turn valve to OFF position. |
|
|
| Remove INSERT and HANDLE SCREW. |
| |
| Slip HANDLE with ADAPTER off. |
|
|
| Remove SPRING CLIP (1). |
|
|
| Lift STOP WASHER (2), turn 90° and replace. |
| |
| Replace SPRING CLIP (1). |
|
|
Replace ADAPTER, HANDLE, SCREW, and INSERT.
AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90°.
Plastic SCREEN (3) in CARTRIDGE (4) may accumulate dirt causing reduced water flow. To clean, first turn off hot and cold water supplies, then:
| Remove INSERT and HANDLE SCREW. | 4 |
| ||
| ||
| Slip HANDLE with ADAPTER off. | |
| ||
| ||
| Unscrew CARTRIDGE (4) with wrench. |
|
|
| |
|
| |
| Thoroughly rinse plastic SCREEN (3) at |
|
|
| |
|
| |
| base of CARTRIDGE (4). |
|
| Replace CARTRIDGE (4) until flange is | 3 |
| ||
| ||
| tight against valve body. | |
| Turn valves OFF. |
|
|
|
Replace ADAPTER, HANDLE, SCREW,
and INSERT.
5 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
34440 REV. 1. 4