American Standard 7191 Series installation instructions EverClean Finish Care Instructions

Models: 7191 Series

1 2
Download 2 pages 10.42 Kb
Page 2
Image 2
EverClean™ Finish Care Instructions





SWING SPOUT ASSEMBLY

CAUTION

Turn off hot and cold water

supplies before beginning.

 

Apply the grease (provided) liberally to the

SPOUT O-RING (1) and SNAP RING (2) areas.

Assemble the SPOUT (3) and tighten the

SPOUT NUT (4) until snug on VALVE BODY.

FITTING INSTALLATION

Remove LOCKNUT (1), BRASS WASHER (2), and

GASKET (3) from fitting.

Place RUBBER RING (4) in recess of fitting.

Insert inlet hoses (on model 7190 only) and

 

 

THREADED SHANK through hole of sink making

MODEL 7190

MODEL 7100

certain RUBBER RING (4) is properly seated in the

recess of the fitting base.

 

 

3

4

2

1

Assemble GASKET (3), BRASS WASHER (2), and LOCKNUT (1) onto the THREADED SHANK from underside of sink deck.

Tighten the LOCKNUT (1) securely.

For Model 7190 Only

Connect the hot water supply to the left inlet hose and the cold water supply to the right inlet hose using appropriate connectors.

For Model 7100 Only

Connect hot or cold water supply lines to shank using sealant, appropriate connectors, and coupling nuts.

RECESS

4

RECESS

SHANK

3

2

HOT1

FLEXIBLE

COLD

SUPPLY

INLET HOSES

NUT

TEST INSTALLED FAUCET

Remove AERATOR.

Operate both handles to flush water lines thoroughly. Checkspout mounting and hose connections for leaks.

With handle in OFF position, turn on water supplies and check all connections for leaks.

Turn handles into OFF position and replace AERATOR.



SERVICE

2

90p

 

 

 

To change direction of handle rotation,

1

proceed as follows:

Manual background Turn valve to OFF position.

Manual background Remove INSERT and HANDLE SCREW.

Manual background Slip HANDLE with ADAPTER off.

Manual background Remove SPRING CLIP (1).

Manual background Lift STOP WASHER (2), turn 90p and replace.

Manual background Replace SPRING CLIP (1).

Manual background Replace ADAPTER, HANDLE, SCREW, and INSERT.

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90p.

Plastic SCREEN (3) in CARTRIDGE (4) may accumulate dirt causing reduced water flow. To clean, first turn off hot and cold water supplies, then:

 

Remove INSERT and HANDLE SCREW.

4

 

 

 

Slip HANDLE with ADAPTER off.

 

 

 

Unscrew CARTRIDGE (4) with wrench.

 

 

 

 

 

 

Thoroughly rinse plastic SCREEN (3) at

 

 

 

 

 

 

base of CARTRIDGE (4).

 

 

Replace CARTRIDGE (4) until flange is

3

 

 

 

tight against valve body.

 

Turn valves OFF.

 

 

 

 

 

Replace ADAPTER, HANDLE, SCREW,

and INSERT.

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

      3 & 7     

Page 2
Image 2