Checklist Before Installation

1.Water Pressure - Not less than 20 nor greater than 120 psi (1.4 - 8.4 bar) constant. (See Engineering Specifications, page 13.)

2.Water Temperature - Not less than 40° nor greater than 120°F (6°- 49° C).

(See Engineering Specifications, page 13.)

3.Minimum Service Flow Rate Available To The Appliance - 3 gpm or equal to the backwash flow rate of your particular model. (See Engineering Specifications, page 13.) For filter installa- tion, refer to page 16 to confirm the backwash rates of the specific model.

4.Drain - Drain the appliance to a floor drain, washer drain, or other suitable waste receptor. To prevent back-siphoning, the installer must provide an adequate air gap or a siphon break. See figure 1.

5.Electricity - The transformer supplied is a standard 115 volt, A.C.

6.Water Quality - If your water supply contains sand, sulfur, bacteria, iron bacteria, man- ganese bacteria, tannins, algae, oil, acid, salt, or other unusual substances, additional support equipment must be installed ahead of the WaterMax appliance unless otherwise indicated on the Engineering Specifications, page 13.