Troubleshooting

Problem

Cause

Solution

Salty water

Plugged injector.

 

Low water pressure.

 

Drain line or flow control is restricted.

 

Brine line restricted or crimped.

 

Excessive amount of water in brine

 

cabinet.

 

Insufficient rinse time.

 

Intermittent pressure drop from feed

 

source.

Clean injector screen, nozzle and throat (See Fig. 6)

Maintain minimum pressure of 30 psi (See Engineering Specs.)

Remove restriction.

Remove restriction, replace if crimped.

Verify correct water level relative to salt setting. Check brine line and fit- tings for loose connections (See Brine Cabinet Data, page 36.)

Check mode setting chart (pg. 14-

15)for proper brine rinse time. Adjust time, if necessary.

Install check valve on the inlet water line to the appliance. (Check local plumbing codes first.)

NOTES:

19

Page 19
Image 19
Hague Quality Water Intl 63BEQ, 63MAQ warranty Salty water Plugged injector Low water pressure