F4,11gineering Specifications
60 SERIES | 63MAQ | 63BEQ | 63MXQ | 63MDQ | 62AMQ |
| 62AKQ | 62AJQ |
|
|
|
|
|
|
|
|
|
Tannin (ppm) | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
|
|
|
|
Sulfur (ppm) - SulfurStat | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
|
|
|
|
|
|
|
|
|
Iron (ppm) - ferrous - clear water • | 0 | 0 | 12 | 0 | 12 | 15 | 5 | |
|
|
|
|
|
|
|
|
|
Maximum Compensated Hardness | 90 | 90 | 110 | 90tt | 90 | 90 | 90 | 60 |
|
|
|
|
|
|
|
|
|
Maximum Chlorine (ppm) | 1 | 3 | 0 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
Minimum pH | NA | NA | 7 | 7 | 7 | 7 | 7 | 6.3 |
|
|
|
|
|
|
|
|
|
Filtration - nominal rating (microns) | 20 | 25 | 20 | 20 | 20 | 20 | 20 | 20 |
|
|
|
|
|
|
|
|
|
#1 Salt - 5850 grains per lb of salt (Ibs./capacity) | 1/5,850 | 1/5,850 | 1.6/9,360 | NA | 1/5,850 | NA | NA | NA |
|
|
|
|
|
|
|
|
|
#2 Salt - 5163 grains per lb of salt (Ibs./capacity) | 2.7/13,890 | 2.7/13,890 | 4.2 /21,680 | NA | 2.7/13,890 | NA | NA | 2.7/13,890 |
|
|
|
|
|
|
|
|
|
#3 Salt - 4679 grains per lb of salt (Ibs./capacity) | 6.2/28,730 | 6.2/28,730 | 9.6/44,840 | 8.5/28,730 | 6.2/28,730 | 6.2/28,730 | 6.2/28,730 | 6.2/28,730 |
|
|
|
|
|
|
|
|
|
#4 Salt - 3828 grains per lb of salt (Ibs./capacity) | 9.3/35,300 | 9.3/35,300 | 14.4/55,090 | 10.7/35,300 | 9.3/35,300 | 9.3/35,300 | 9.3/35,300 | 9.3/35,300 |
|
|
|
|
|
|
|
|
|
Media Amount Compartment #1 | 1.5 lbs. | 2.0 lbs. | 1.5 lbs. | 1.5 lbs. | NA | NA | NA | NA |
|
|
|
|
|
|
|
|
|
Media Amount Compartment #2 | Empty | .4 cu.ft. | .6 cu.ft. | .3 cu.ft. | 6 Ibs. | 27 Ibs. | .4 cuft. | .4 cu.ft. |
|
|
|
|
|
|
|
|
|
Media Amount Compartment #3 | 1.06 cu.ft. | 1.06 cu.ft. | 1.06 cu.ft. | 1.06 cu.ft | 1.06 cuff. | 1.06 cu.ft. | 1.06 cuff. | 1.06 cu.ft. |
|
|
|
|
|
|
|
|
|
Drain Line Flow Control (gpm)@ min. water presure | 2.41 | 3t | 2.4t | 2.4t | 5t | Empty | 7t | 7t |
|
|
|
|
|
|
|
|
|
Brine Line Flow Control Refill (gpm) | .5 | .5 | .5 | .5 | .5 | .5 | .5 | .5 |
|
|
|
|
|
|
|
|
|
Water Pressure | ||||||||
|
|
|
|
|
|
|
|
|
Flow Rate @ 25 psi drop | 19.5 | 19.5 | 17 | 17 | 23 | 19.6 | 19.6 | 20.5 |
|
|
|
|
|
|
|
|
|
Flow Rate @ 15 psi drop# | 11 | 13 | 10.5 | 10.5 | 11.2 | 10.6 | 10.6 | 12.5 |
|
|
|
|
|
|
|
|
|
Pressure Drop @ Flow Rate Of 4 gpm | 6.5 psi | 8.5 psi | 8.5 psi | 8.5 psi | 3.2 psi | 6 psi | 6 psi | 7 psi |
|
|
|
|
|
|
|
|
|
(#1 Salt setting) total length of reg. Min / gal | 12/13.5 | 12/16 | 12/13.5 | NA | 12/24 | NA | NA | NA |
|
|
|
|
|
|
|
|
|
(#2 Salt setting) total length of reg. Min / gal | 18/16.5 | 18/19 | 26/20.5 | NA | 18/27 | NA | NA | 23/70 |
|
|
|
|
|
|
|
|
|
(#3 Salt setting) total length of reg. Min / gal | 38/26.5 | 38/29.5 | 58/36.5 | 47/31 | 38/37 | 44/80 | 44/80 | 44/80 |
|
|
|
|
|
|
|
|
|
(#4 Salt setting) total length of reg. Min / gal | 56/35.5 | 56/38 | 74/44.5 | 64/39.5 | 58/56 | 61/89 | 61/89 | 61/89 |
|
|
|
|
|
|
|
|
|
Shipping weight (Ibs.) | 135 | 152 | 168 | 152 | 140 | 167 | 160 | 180 |
|
|
|
|
|
|
|
|
|
Bacteriostatic - KDF® Process Media - Listed |
| YES | YES | YES | YES | YES | YES | YES |
With The U.S. EPA As A Bacteriostatic Device. | YES | |||||||
U.S. EPA |
|
|
|
|
|
|
|
|
Valve Inlet/Outlet 1"
Drain Line (Minimum ID.) %Y "
Water Temperature
Floor Space (inches) 15" x 30"
Salt storage capacity: 200 Ibs, 90kg Brine
Brine Draw: .25 gpm
Rinse: .4 gpm
Electrical rating: 115V, 60 cycle. Iron Reduction To .3 ppm Or Less.
When Adding Media In The Field, Check For Proper Settings (See Specifications, Above.)
Regeneration Every 96 Hours Is Required When Iron Is Present In The Raw Water Supply. Use Salt Setting #3 Or #4.
of 200 ppm TDS.
Retainer. Must Have A Minimum Of 7 gpm @ 30 psi Available For Proper Backwash.
Will Add Additional Hardness To Water Before Softening.
tRate Of Flow Must Be Verified At The End Of %Y" ID Drain Line.
ttAn y Hardness Over 10 gpg Will Increase The Chance Of Calcium Carbonate Precipitation. As The Hardness Increases So Does The Chance Of This Precipitation. Must Use Citric Acid to Regenerate Along With Salt.
13