Hague Quality Water Intl 63BEQ, 63MAQ warranty F4,11gineering Specifications

Models: 63MAQ 63BEQ

1 36
Download 36 pages 13.1 Kb
Page 13
Image 13

F4,11gineering Specifications

60 SERIES

63MAQ

63BEQ

63MXQ

63MDQ

62AMQ

 

62AKQ

62AJQ

 

 

 

 

 

 

 

 

 

Tannin (ppm)

0

0

0

0-2

0

0

0

0

 

 

 

 

 

 

 

 

 

Sulfur (ppm) - SulfurStat

0

0

0

0

0

0-5

0

0

 

 

 

 

 

 

 

 

 

Iron (ppm) - ferrous - clear water •

0

0

12

0

12

2-12

15

5

 

 

 

 

 

 

 

 

 

Maximum Compensated Hardness

90

90

110

90tt

90

90

90

60

 

 

 

 

 

 

 

 

 

Maximum Chlorine (ppm)

1

3

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

Minimum pH

NA

NA

7

7

7

7

7

6.3

 

 

 

 

 

 

 

 

 

Filtration - nominal rating (microns)

20

25

20

20

20

20

20

20

 

 

 

 

 

 

 

 

 

#1 Salt - 5850 grains per lb of salt (Ibs./capacity)

1/5,850

1/5,850

1.6/9,360

NA

1/5,850

NA

NA

NA

 

 

 

 

 

 

 

 

 

#2 Salt - 5163 grains per lb of salt (Ibs./capacity)

2.7/13,890

2.7/13,890

4.2 /21,680

NA

2.7/13,890

NA

NA

2.7/13,890

 

 

 

 

 

 

 

 

 

#3 Salt - 4679 grains per lb of salt (Ibs./capacity)

6.2/28,730

6.2/28,730

9.6/44,840

8.5/28,730

6.2/28,730

6.2/28,730

6.2/28,730

6.2/28,730

 

 

 

 

 

 

 

 

 

#4 Salt - 3828 grains per lb of salt (Ibs./capacity)

9.3/35,300

9.3/35,300

14.4/55,090

10.7/35,300

9.3/35,300

9.3/35,300

9.3/35,300

9.3/35,300

 

 

 

 

 

 

 

 

 

Media Amount Compartment #1

1.5 lbs.

2.0 lbs.

1.5 lbs.

1.5 lbs.

NA

NA

NA

NA

 

 

 

 

 

 

 

 

 

Media Amount Compartment #2

Empty

.4 cu.ft.

.6 cu.ft.

.3 cu.ft.

6 Ibs.

27 Ibs.

.4 cuft.

.4 cu.ft.

 

 

 

 

 

 

 

 

 

Media Amount Compartment #3

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft.

1.06 cu.ft

1.06 cuff.

1.06 cu.ft.

1.06 cuff.

1.06 cu.ft.

 

 

 

 

 

 

 

 

 

Drain Line Flow Control (gpm)@ min. water presure

2.41

3t

2.4t

2.4t

5t

Empty

7t

7t

 

 

 

 

 

 

 

 

 

Brine Line Flow Control Refill (gpm)

.5

.5

.5

.5

.5

.5

.5

.5

 

 

 

 

 

 

 

 

 

Water Pressure (min-max psi)

20-120

20-120

20-120

20-120

20-120

30-120

30-120

30-120

 

 

 

 

 

 

 

 

 

Flow Rate @ 25 psi drop

19.5

19.5

17

17

23

19.6

19.6

20.5

 

 

 

 

 

 

 

 

 

Flow Rate @ 15 psi drop#

11

13

10.5

10.5

11.2

10.6

10.6

12.5

 

 

 

 

 

 

 

 

 

Pressure Drop @ Flow Rate Of 4 gpm

6.5 psi

8.5 psi

8.5 psi

8.5 psi

3.2 psi

6 psi

6 psi

7 psi

 

 

 

 

 

 

 

 

 

(#1 Salt setting) total length of reg. Min / gal

12/13.5

12/16

12/13.5

NA

12/24

NA

NA

NA

 

 

 

 

 

 

 

 

 

(#2 Salt setting) total length of reg. Min / gal

18/16.5

18/19

26/20.5

NA

18/27

NA

NA

23/70

 

 

 

 

 

 

 

 

 

(#3 Salt setting) total length of reg. Min / gal

38/26.5

38/29.5

58/36.5

47/31

38/37

44/80

44/80

44/80

 

 

 

 

 

 

 

 

 

(#4 Salt setting) total length of reg. Min / gal

56/35.5

56/38

74/44.5

64/39.5

58/56

61/89

61/89

61/89

 

 

 

 

 

 

 

 

 

Shipping weight (Ibs.)

135

152

168

152

140

167

160

180

 

 

 

 

 

 

 

 

 

Bacteriostatic - KDF® Process Media - Listed

 

YES

YES

YES

YES

YES

YES

YES

With The U.S. EPA As A Bacteriostatic Device.

YES

U.S. EPA #54369-OH-001

 

 

 

 

 

 

 

 

Valve Inlet/Outlet 1"

Drain Line (Minimum ID.) %Y "

Water Temperature (Min-Max) 40-120 °F Height (inches) 38-1/4"

Floor Space (inches) 15" x 30"

Salt storage capacity: 200 Ibs, 90kg Brine

Brine Draw: .25 gpm

Rinse: .4 gpm

Electrical rating: 115V, 60 cycle. Iron Reduction To .3 ppm Or Less.

When Adding Media In The Field, Check For Proper Settings (See Specifications, Above.)

Regeneration Every 96 Hours Is Required When Iron Is Present In The Raw Water Supply. Use Salt Setting #3 Or #4.

of 200 ppm TDS.

Retainer. Must Have A Minimum Of 7 gpm @ 30 psi Available For Proper Backwash.

Will Add Additional Hardness To Water Before Softening.

tRate Of Flow Must Be Verified At The End Of %Y" ID Drain Line.

ttAn y Hardness Over 10 gpg Will Increase The Chance Of Calcium Carbonate Precipitation. As The Hardness Increases So Does The Chance Of This Precipitation. Must Use Citric Acid to Regenerate Along With Salt.

13

Page 13
Image 13
Hague Quality Water Intl 63BEQ, 63MAQ warranty F4,11gineering Specifications