Setting And Using The Appliance Control (cont.)
6.00.
6,OOa
6.00b
Push the NEXT button to step to the next parameter. The display will show: Hard. Gr. 040 The 040 is the hardness number of the water tested. This number is to be the actual hardness reading and is not compensated for iron.
Push and release the SELECT DIGIT button until the cursor ( ) is positioned in the display as follows: Hard. Gr. Q40. The cursor is now under the "ten" position.
Continue pushing the SELECT and CHANGE buttons until the desired hardness number is displayed.
Example: Hard. Gr. 025
LPush the NEXT button to step to the next parameter. The display will show: Iron ppm 00 This parameter is used to calculate a compensated hardness automatically.
7.00a Push the SELECT and CHANGE buttons until the desired iron number is displayed. Example: Iron ppm 02
8.00Push the NEXT button to step to the next parameter. The display will show: Mang. ppm 00
8.00a Push the SELECT and CHANGE buttons until the desired manganese number is displayed. Example: Mang. ppm QO
8.00b Push the NEXT button to step to the next parameter. The display will show: SALT = Sodium.
WARNING! When iron and/or manganese is present in the water supply, we do not recommend using potassium chloride as a regenerant. Iron and/or manganese bacteria may develop and foul the conditioning media and may void the warranty.
8.00c Push the SELECT and CHANGE buttons until the desired regenerant is selected. EXAMPLE: Salt = Sodium.
9,00 Push the NEXT button to step to the next parameter. The display will show: Comp. Hard. 00033
This parameter is the calculated compensated hardness using the hardness, iron and manganese settings. The formula is (4 x each ppm iron) + (4 x each ppm manganese) + hardness = compensated hardness. This is not a parameter that can be set. The display should now read: Comp. Hard. 00033
10.00Push the NEXT button to step to the next parameter. The display will show: Capty. Gr. 28730
This parameter is used to set the softening capacity of the appliance. (See WaterMax engineering specifications or setting charts for capacities based on salt usage.)
10.00a Push the SELECT and CHANGE buttons until the desired capacity number is displayed. In this example, set to: Capac. Gr. 28730
11.00Push the NEXT button to step to the next parameter. The display will show:
This parameter, if set to "Yes", is used to force the appliance to regenerate every 96 hours if regularly scheduled regenerations based on water usage do not occur in 96 hours or less intervals. This should always be "yes" if iron is present in the water.
11.00a | Push CHANGE button to toggle parameter value from "No" to "Yes". In this example, set to: 96hr Regen Yes |
12.00 | Push the NEXT button to step to the next parameter. The display will show: Distill/RO Yes |
| Set this parameter to "Yes" if a distiller or reverse osmosis system is plumbed to use soft water from |
| the WaterMax. |
12.00a | Push the CHANGE button to toggle parameter value from "No" to "Yes". In this example, set to: Distill/RO Yes |
13.0Push the NEXT button to step to the next parameter. The display will show: Backwash 1 Q1.0
(See WaterMax setting chart.) The "01.0" is the time, in minutes to the nearest tenth, for which the first backwash cycle can be set.
13.00a Push the SELECT and CHANGE buttons until the desired backwash time is displayed. In this example, set to: Backwash 1 07.0
11