WaterMax Filters
WaterMax Filters Application Chart
Capacity (ppm)
Sulphur H 2 S (2 ppm)
Iron (ppm)
Minimum pH
Media type
Media amount (cu. ft.)
Cont. flow rate (gpm)
Peak flow rate (gpm)
Backwash rate (gpm)
Brine line flow control (gpm)
Water pressure
Mode settings
Backwash #1 (min)
Brine/rinse (min)
Backwash #2 (min)
Salt (lbs.2 3 b. a It setting = 4oz. KMnO4
Regenerant used
Flow rate at 25 PSI drop
Flow rate at 15 PSI drop
Recommended service flow 3 @ pressure drop
|
|
|
|
|
61 AAN | 61 AAE | 61 AAR | 61 AAS | 61 AAF |
| ||||
10,000 | N/A | N/A | N/A | N/A |
|
|
|
|
|
5 | N/A | N/A | N/A | N/A |
|
|
|
|
|
20 | N/A | N/A | N/A | N/A |
|
|
|
|
|
7 | N/A | N/A | 5 | N/A |
|
|
|
|
|
Manganese | Activated Carbon | Filter Ag | Calcite/Corsex | |
Greensand |
|
|
|
|
1.25 | 1 | 1.25 | 1.25 | 1 |
|
|
|
|
|
6 | 6 | 6 | 6 | 6 |
|
|
|
|
|
10 | 10 | 10 | 10 | 12 |
|
|
|
|
|
7 | 5 | 5 | 7 | 7 |
|
|
|
|
|
.5 | N/A | N/A | N/A | N/A |
|
|
|
|
|
|
|
|
|
|
1 | 1 | 1 | 1 | 1 |
|
|
|
|
|
5 | 7 | 7 | 7 | 7 |
|
|
|
|
|
45 | 0 | 0 | 0 | 0 |
|
|
|
|
|
3 | 0 | 0 | 0 | 0 |
|
|
|
|
|
3 | 0 | 0 | 0 | 0 |
|
|
|
|
|
4 oz. | N/A | N/A | N/A | N/A |
KMnO4 |
|
|
|
|
16.7 GPM | 21.4 GPM | 21.5 GPM | 20.4 GPM | 19.4 GPM |
|
|
|
|
|
10.5 GPM | 15.9 GPM | 15.9 GPM | 15.2 GPM | 15.1 GPM |
|
|
|
|
|
4.5 GPM @ | 3.6 GPM @ | 4.5 GPM @ | 4.5 GPM @ | 3.6 GPM @ |
4.7 PSI | 1.1 PSI | 1.5 PSI | 1.8 PSI | 1.5 PSI |
Removes iron | Removes | Removes | Will raise the | Removes |
and iron algae. | tastes, odors | suspended | pH of most low | suspended |
Also removes | and will reduce | matter | pH water. The | matter |
up to 5 ppm | most man- | (turbidity) from | mineral media | (turbidity) from |
Hydrogen | made | water down to | must be | water down to |
Sulfide with | pollutants. | the | replenished | nominal 20 |
the presence | Backwash | micron range. | periodically to | microns. |
of 2 ppm iron. | every 3 days | Backwash | maintain | Backwash |
Regenerate | or as needed. | every 3 days | optimum bed | every 3 days |
every 6 days | WARNING! | or as needed. | depth for | or as needed. |
for iron; as |
| effective |
| |
Must not be |
|
| ||
needed for |
| correction. |
| |
backwashMust not ed |
|
| ||
Hydrogen |
| Backwash |
| |
for 24 hours |
|
| ||
Sulfide |
| every 2 days to |
| |
after |
|
| ||
(sulfur), |
| prevent |
| |
installation. |
|
| ||
|
| solidification of |
| |
|
|
|
|
1The
2CAUTION: follow the instructions on the KMnO4 container.
3For optimum water quality, do not exceed recommended service flow rate for filter media type.
16