American Standard 7222.712, 7222.732, 7222.722 installation instructions Installation Instructions

Models: 7222.712 7222.732 7222.722

1 3
Download 3 pages 49.83 Kb
Page 1
Image 1
Installation Instructions

Installation Instructions

TWO HANDLE BATH/SHOWER SET

7220.702 7221.722

7220.712 7221.732

7220.722 7222.702

7220.732 7222.712

7221.702 7222.722

7221.712 7222.732

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly-- please read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1M U.S. Patent No. 5,819,789

US60406 REV. 1. 2

ROUGHING-IN DIMENSIONS

NOTE: NO CONCEALED PIPING FURNISHED

1

ROUGHING-IN

 

Turn off hot and cold water

CAUTION

SHOWER AND SPOUT

supplies before beginning.

 

 

1-1/4 DIA HOLE

1/2" N.P.T.

SHOWER ARM TWO HANDLE BATH/SHOWER SET

OPTIONAL TO FINISHED

FLOOR USUALLY

BETWEEN 65'' AND 78''

2" MIN. 3-1/4" MAX.

1/2" N.P.T. TO

SHOWER

CROSS 7220.702 7221.722 BRACE

1-3/4Manual background 1-3/4 TYP.

UNION INLET

1/2"-14 N.P.T.

4"

1/2" COPPER

Manual background FINISHED

WALL

5 REF.

 

7 REF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) 1-13/16" DIA. HOLES

HEAD

 

FOR VALVES ON 8"

FOR

 

 

CENTERS (1) 1-13/16"

 

DIA. HOLE FOR CENTER

 

TRANSFER VALVE

74

 

 

 

 

 

 

 

18 OPTIONAL

Manual backgroundManual background 1" MIN.

 

 

 

5-1/8"

4

REF.

 

 

TOP OF

TUB RIM

IMPORTANT: DO NOT REMOVE PLASTER GUARDS (2) UNTIL STEP 2.

Prepare water supplies per Roughing-in Dimensions. Apply sealing tape to all threaded connections.

Install VALVE (1) at indicated height and depth. Make sure the outlet marked "SHR" is pointing upward. Mount VALVE (1) to cross brace with wood screws.

Slip COUPLING NUT over supply pipe and thread UNION SWIVEL to pipe. Connect HOT (6) water supply to LEFT valve inlet and COLD (7) water supply to RIGHT valve inlet.

Prepare SHOWER RISER (4) and ELBOW (3). Connect to TOP outlet, marked "SHR" of VALVE BODY (1).

Prepare TUB FILLER PIPE (8), ELBOW (10) and roughing-in COPPER PIPE (9). Connect to BOTTOM outlet of VALVE BODY (1).

Add cross braces to wall structure and secure piping.

Cap NIPPLES (5) and COPPER PIPE (9). Open supply lines and check for leaks. Remove PLASTER GUARDS (2). Use spline on end of PLASTER GUARD (2) to open both VALVES and check for leaks.

Close both valves and turn off water supplies. Replace PLASTER GUARDS (2). Finish wall construction.

 

 

3

 

 

5

 

 

4

 

 

CROSS

 

 

BRACE

 

 

(SHR)

 

"HOT"

1

"MAX WALL"

 

 

 

 

MAX

 

 

WA

 

 

L

 

 

L

 

 

M

 

 

I

 

 

N

 

2

1

 

-

 

5

 

/

 

8"

 

DE EP

 

 

 

BOTTOM OF TUB

Recommended Tools

Manual background Flat Blade Screwdriver Phillips Screwdriver

Manual background Adjustable Wrench

Plumbers' Putty or Caulking

Channel Locks

*Hex key Supplied with Fitting

PLASTER

"COLD"

GUARD

MAX

WA

L

 

L

 

M

 

I

 

N

 

1

 

-

 

5

 

/

 

8"

6

DE EP

UNION

 

SWIVEL

87

9COUPLING

Manual backgroundManual backgroundManual background10 Manual backgroundManual background NUT

"COLD"

Page 1
Image 1
American Standard 7222.712, 7222.732 installation instructions Installation Instructions, Two Handle Bath/Shower Set