American Standard 7272.851, 7272.850, 7272.821 Care Instructions, Tools And Supplies Required

Models: 7272.820 7272.851 7272.821 7272.850

1 3
Download 3 pages 60.74 Kb
Page 2
Image 2
TOOLS AND SUPPLIES REQUIRED
M 9 6 8 4 8 8

TOOLS AND SUPPLIES REQUIRED

 

 

Teflon Tape

Channel Locks

Adjustable Wrench

Drill

Plumbers' Putty or

 

 

Caulking

1 INSTALL DECK MOUNT LABORATORY FITTINGS

CAUTION

Turn off hot and cold water supplies before beginning.

Drill two 1-1/8" dia. holes in mounting surface if required per rough-in dimensions.

Assemble rubber washers onto fitting shanks.

Insert fitting shanks through holes of mounting surface.

Assemble steel washers and lock nuts onto fitting shanks. Align fitting and tighten lock nuts securely with wrench.

2

MAKE WATER SUPPLY CONNECTIONS

IMPORTANT: FLUSH ALL SUPPLY LINES PRIOR TO

FITTING INSTALLATION.

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS

MUST BE PURCHASED SEPARATELY.

Connect water supplies to faucet with 3/8" O.D. bull-nose risers or 1/2" IPS flexible supplies. Use adjustable wrench

kink copper supply when bending. Use tubing cutter to cut to proper length.

After installation is complete turn service on and check all connections for leaks.

1 INSTALL DECK MOUNT LABORATORY FITTINGS FITTING

FITTING

FLANGE

FITTING

SHANK

RUBBER

WASHER

STEEL Assemble rubber washers onto fitting shanks.

WASHER

LOCK NUT MAKE WATER SUPPLY CONNECTIONS

3/8" O.D. BULL-NOSE RISER 1 INSTALL WALL MOUNT LABORATORY FITTINGS

OR 1/2" IPS FLEXIBLE SUPPLIES

COUPLING NUT for installation and must be ordered separate wall escutcheon onto  union swivels

SUPPLIED WITH

FITTING

1 INSTALL WALL MOUNT LABORATORY FITTINGS

CAUTION

Turn off hot and cold water supplies before beginning.

for installation and must be ordered separate

Use appropriate

CARE INSTRUCTIONS: wall escutcheon onto Manual backgroundManual background union swivels

with Manual backgroundManual background

adjustable wrench untilare flush against finished wall.

Note: Center to center dimension of swivel nuts are 8" [203mm].

WALL

ESCUTCHEON

COLD

Manual background SWIVEL

8"

[203mm]

MTG. SHANK KIT RDERED SEPARATELY)

M962325-0070A

UNION

SWIVELS

2

 

MAKE WATER SUPPLY CONNECTIONS

 

IMPORTANT: FLUSH ALL SUPPLY LINES PRIOR TO

 

 

FITTING INSTALLATION.

Align Manual background to swivel nuts, if swivel nuts don't align with

Insert Manual background into swivel nuts if not already installed. Tighten both swivel nuts to make water tight connections.

Complete installation, turn on water and check for leaks.

FITTING INLET

SEAL WASHER

SWIVEL

NUT

Manual background UNION

SWIVEL

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

Page 2
Image 2
American Standard 7272.851 Care Instructions, Tools And Supplies Required, Install Deck Mount Laboratory Fittings