CONSOLE TABLE INSTALLATION
Identify desired location of the console table.
Provide suitable reinforcement required for anchoring the vanity to the wall. Centerline of reinforcement should be 30" up from the floor (see Figure 1).
Rough in supply lines and waste per rough in dimensions.
Drill at least two 3/8" O.D. anchoring holes through the rear stringer of the console table at
Move the vanity into place and level with the adjustable glides on the bottom of the feet. The glides can be adjusted outward up to 3/8". Anchor it to the wall through the 2 anchoring holes in the rear of the vanity (see Figure 2). Do not overtighten to prevent cracking the rear stringer.
C/L of 2 x 6
Reinforcement
| 30" |
FIGURE 1 | 762mm |
|
Finished
Floor
| |
| 489mm |
| |
| 64mm |
FIGURE 2 |
|
ADJUSTABLE |
|
GLIDES |
|
(LOCATED |
|
UNDER | 3/8" ANCHORING |
EACH FOOT) | HOLES IN |
| REAR STRINGER |
| MOLDING |
VANITY TOP, SINK, AND FAUCET INSTALLATION
Install the faucet onto the granite top per the manufacturer's instructions. | GRANITE TOP |
Two people recommended for this installation
SEALANT
Apply a continuous 1/8" bead of silicone sealant 1" from the inside edge of the console. Carefully set the stone top on the console table. Be sure that the top is centered on the table.
Use mineral spirits to remove excess silicone from the console and stone top.
- 2 - | 752877 - 100 REV . A |