Replacing An Ionizing Wire
If an ionizing wire should break, it can be replaced as follows:
1.Remove all pieces of broken wire. Make sure supports at each end are in good condition and not bent out of
shape.
2. Hook the new wire onto the support at |
|
one end. | Support |
3.Hold your finger against the support at the other end and hold the ionizing wire between thumb and forefinger as shown or use needle nose pliers. Press on spring and on wire loop until it slips over the end of the support. Make sure wire is securely anchored at each end.
Ionizing Wire
TROUBLESHOOTING
INDICATION |
| SERVICE CHECKS |
| ACTION |
|
|
|
| |
• On/Off switch “ON” | None |
| Normal Standby Operation. | |
• Green light “OFF” |
|
|
|
|
• Blower Off |
|
|
|
|
• On/Off switch “ON” | None |
| Normal Operation. | |
• Green light “ON” |
|
|
|
|
• Blower On |
|
|
|
|
• On/Off switch “ON” | AC Power is not being supplied to air cleaner. |
|
| |
• Green light “OFF” | 1. | Check that power cord is properly connected to | 1. | Make proper power cord connections. |
• Blower On |
| power pack and to outlet. |
|
|
| 2. | Check for voltage at air cleaner outlet box. If | 2. | Replace fuse or reset circuit breaker. |
|
| none, check fuse or circuit breaker at power |
|
|
|
| input line. |
|
|
| 3. | Check that fuse in power pack is not blown | 3. | Replace Fuse. |
| 4. | Check for shorted collecting cell by installing | 4. | Wash cells. If short is not corrected, |
|
| power door with collecting cells removed and |
| call for service. |
|
| only |
|
|
|
| cell is shorted. |
|
|
| 5. | Check for dirt or blockage in air sensor tube. | 5. | Clean air sensor tube. |
| 6. | Check that | 6. | Replace damaged filter |
|
| damaged. |
|
|
|
|
|
| |
• On/Off Switch “ON” | 1. Check for dirty collecting cells. Check cells for any | 1. | Remove cells and wash thoroughly. | |
• Green light flickering | foreign object that might be lodged between plates |
|
| |
• Blower On | of cell. |
|
| |
| 2. Check cells for broken ionizing wires, cracked | 2. | Replace broken ionizing wires. | |
| insulator, or bent plates. |
| Replace cell if insulator cracked or | |
|
|
|
| plates bent. |
| 3. All ionizing wires must be completely clean with no | 3. | Clean ionizing wires. | |
| dust |
|
| |
|
|
|
|
|
Page 5