AFWALL® 1.6 GPF
FLUSHOMETER TOILET SYSTEM
| with EVERCLEAN® |
BARRIER FREE | MANUAL FLUSH VALVE |
AFWALL® 1.6 GPF
FLUSHOMETER TOILET SYSTEM with EVERCLEAN®
❏2856.016 1.6 gpf Exposed Top Spud Bowl and Manual Flush Valve
BOWL:
•
•Vitreous china
•High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf)
•Meets definition of HET (High Efficiency Toilet) when used with a high efficiency flush valve (1.28 gpf or 1.6 / 1.1 gpf Dual Flush)
•Permanent EverClean® surface inhibits the growth of stain- and
•Condensation chanel
•
•
•Fully glazed
•10" x 12" water surface area
•100% factory flush tested
•Bolt caps and seat not included
•Model 3351.001
MANUAL FLUSH VALVE:
•Manual
•
•Piston operation delivers superior flush accuracy and repeatability
•Piston valve remains closed and does not need to be reset after loss of water pressure
•
•Positive seal ensures
•No external volume adjustment
•Durable
•
•Adjustable tailpiece for
•Can be installed left or right handed
•Model 6047.161.002
Includes:
•
•1" I.P.S. angle stop with
•Sweat solder kit including cover tube and wall flange
•High back pressure vacuum breaker with down tube
•Spud coupling & flange for
To Be Specified:
❏Color: ❏ White
❏Seat: 5901.100 American Standard Seat
❏5901.110 American Standard Seat with EverClean®
❏Alternate Seat: 5905.100 Heavy Duty
American Standard Seat
❏5905.110 Heavy Duty American Standard Seat with EverClean
❏Carrier Fitting (by others):
N63
© 2011 AS America Inc.
SEE REVERSE FOR
System MaP* Score:
•1,000 grams of miso @ 1.6 gpf
*Maximum Performance (MaP) testing performed by IAPMO R&T Lab. MaP Report conducted by Veritec Consulting, Inc. and Koeller and Company.
Operating Pressure:
Overall Range:
Recommended: 25 psi
**Water pressure over 80 psi is not recommended for most plumbing fixtures.
Flow Requirement:
25gpm (94.6 L/min.)
Nominal Fixture Dimensions:
635 x 375 x 381mm (25" x
Fixture Compliance Certifications -
Meets or Exceeds the Following Specifications:
•ASME
Valve Listings:
•ASSE 1037
•ANSI/ASME A112.19.2
•ADA Compliant
Revised 11/11