4 TEST INSTALLED FAUCET
Move HANDLE (1) into "off" position.
Unthread SPRAY HOSE (3) from SPRAY (2).
Turn on water supplies and check connections for leaks.
Hold HOSE END (3) in sink and operate HANDLE (1) on and off, hot and cold to flush water lines thoroughly. Replace SPRAY (2).
Pull SPRAY (2) out and check hose and supply connections
for leaks. Check that SPRAY HOSE (3) and WEIGHT (4) slide up and down freely and do not interfear with supplies or waste outlet plumbing. With faucet on push BUTTON (5) to spray and aerator fuctions.
Check all drain connections for leaks.
Move HANDLE (1) to "off" position.
| 3 |
|
2 | 5 | 1 |
|
4 3
HOT & COLD SUPPLIES
5 SERVICE
Clogged CARTRIDGE outlets or inlets may cause reduced flow. To clean, first turn off water supply then:
Loosen and remove LEVER HANDLE (1). Loosen HANDLE
SCREW (2) with 2.5mm Hex Wrench and then pull HANDLE
BASE (3) off.
Unthread ESCUTCHEON CAP (4). Unthread the | 11 |
CARTRIDGE NUT (5). |
Remove CARTRIDGE (6). Clean inlets of CARTRIDGE (6) and MANIFOLD (7).
Reassemble CARTRIDGE (6). Replace CARTRIDGE
NUT (5), CAP (4) and HANDLE assembly, check flow.
If SPOUT (11) leaks at swivel point the
Disconnect SPRAY HOSE (8) from CONNECTING NUT (9).
Loosen the SPOUT SET SCREW (10) with a 3mm Hex wrench.
Rotate the SPOUT (11) side to side while pulling upward to remove SPOUT (11) from faucet body. Remove SPRAY HOSE (8).
Replace the defective parts and grease
Check that SPOUT (11) rotates freely and does not leak at the swivel point.
REMOVE
INSTALL
12 |
|
10 | 1 |
3mm |
HEX WRENCH
|
| CLEAN | 5 |
|
| ||
|
|
| |
|
|
| 4 |
7 |
|
| 2 |
|
|
|
6
3
9 8
6 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.