American Standard Proximity Faucet HOW TO CLEAN FILTER Fig, Caution do not over tighten strainer

Models: Proximity Faucet

1 12
Download 12 pages 31.19 Kb
Page 9
Image 9
4 HOW TO CLEAN FILTER; Fig. 4

4 HOW TO CLEAN FILTER; Fig. 4

CAUTION Before opening ENCLOSURE disconnect AC power supply.

1.Remove ENCLOSURE COVER.

2.Close SUPPLY STOP (5) with 4mm Hex wrench. Note: Keep water flowing out of faucet while shutting off.

3.Pull off Red (1) and Black (2) CONNECTORS from SOLENOID VALVE (3).

4.Unthread STRAINER (4) using a 7/16" socket.

5.Pull out the STRAINER (4) and clean with an old toothbrush. Rinse thoroughly with water.

6.Install the STRAINER (4) back in its place and tighten with a 7/16" socket.

Caution: do not over tighten strainer.

Note: It is recommended to clean strainer every 6 months.

7.Replace ENCLOSURE COVER. Tighten cover screws firmly.

5HOW TO CLEAN AND REMOVE THE AERATOR; Fig. 5

1.Remove AERATOR HOUSING (1) with KEY supplied with faucet.

3.Remove AERATOR (2) from HOUSING (1).

2.Clean the AERATOR SCREENS (3) with a old tooth brush to remove dirt.

4.Rinse Clean with water. Reassemble and install into spout end. Be sure black seal washer is in place.

6HOW TO CONVERT RIGID GOOSE NECK SPOUT TO SWING SPOUT Fig. 6

The GN SPOUT is shipped from the factory as a rigid assembly. To convert the GN SPOUT into a SWING SPOUT proceed as follows:

1.Remove SET SCREW (1) from back of GN SPOUT

(2) with a flat blade screwdriver. Fig. 6.

2.Install SWIVEL SET SCREW (3) into opening in the GN SPOUT (2). SWIVEL SET SCREW (3) is found in hardware bag within product box.

Fig.4

3

4

CLEAN

SCREENS

2

1

5

4

 

 

Fig.5

Fig.53

1

2

Fig.6

2

1Caution: do not over tighten strainer.

3 (USE SHORT SET SCREW FOR SWIVEL SPOUT)

8

Page 9
Image 9