American Standard T038.50X EverClean Finish Care Instructions, Service, Back To Back Installation

Models: T038.50X

1 3
Download 3 pages 29.7 Kb
Page 3
Image 3
SERVICE

SERVICE

4

If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE (1) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:

Remove HANDLE (2).

)

0''

$

7

1

5

3

Remove two SCREWS (6) holding ESCUTCHEON (7)

6

and remvoe ESCUTCHEON (7).

 

Remove CAP (3), SCREWS (5) and CARTRIDGE (1).

 

Clean inlets and MANIFOLD (4).

 

Reassemble CARTRIDGE (1), alternately tightening SCREWS (5).

2

Replace CAP (3) and HANDLE (2). Check flow.

SERVICE: VALVE LEAKS WHEN SHUT OFF

SERVICE: VALVE LEAKS WHEN SHUT OFFUNABLE TO MAINTAIN CONSTANT TEMPERATURE Remove handle and trim.

BACK TO BACK INSTALLATIONEverClean™ Finish Care Instructions Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit.

Manual backgroundManual background Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).

Manual backgroundManual background Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Manual backgroundManual background Turn on water supply and see above for installing TRIM and HANDLE.

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

Manual backgroundManual background Remove PRESSURE BALANCE UNIT (5).

Manual backgroundManual background Remove CAPS (7) and clean valve thoroughly.

Manual backgroundManual background Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective.

Manual backgroundManual background Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting.

BACK TO BACK INSTALLATION

Manual backgroundManual background Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down.

Manual backgroundManual background Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting.

Manual backgroundManual background Reassemble FIXATION RING (4) and CARTRIDGE (1).

6

4

 

 

1

LARGE OUTLET

8

7

 

5

 

 

 

 

 

 

5

3

INLETS

 

 

2

 

 

9

 

 

 

ROTATE 180˚

BACK TO BACK INSTALLATION

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface. .      

Page 3
Image 3
American Standard T038.50X EverClean Finish Care Instructions, Service Valve Leaks When Shut Off