American Standard T050.210 Trim Installation, Temperature Calibration, Set Hot Limit Stop

Models: T050.210

1 9
Download 9 pages 13.93 Kb
Page 2
Image 2
1 TRIM INSTALLATION

1 TRIM INSTALLATION

2

1

Push CAPS (1) over the O-RING SEALS (2).

Push ESCUTCHEON HOLDER (3) with lightly greased O-RING SEAL (4) over CAP (1).

Push on ESCUTCHEON (5) and attach with (60mm) SCREWS (6) to valve body.

3 4

 

 

 

N

 

 

PE

 

P/

O

 

O

 

 

T

 

 

 

6

5

1

4

2 HANDLE INSTALLATION

Push TEMPERATURE-CONTROL KNOB (1) with the red stop onto KNOB MOUNT (2). Push RING (3) onto TEMPERATURE-CONTROL KNOB (1) and attach with SCREW (4).

Push VOLUME-CONTROL KNOB (6) onto HANDLE ADAPTER (8). Push RING (3) onto VOLUME-CONTROL KNOB (6) and and attach with SCREW (7).

Press on KNOB CAPS (5).

3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION

Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:

3 TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION4 TEMPERATURE CALIBRATION Shut off water supply.

SET HOT LIMIT STOPOPERATING THE VALVE Remove handle and rim

Manual background Remove check stops and re-install them transposed.

Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.

Turn the water supply back on and perform the temperature adjustment in step 4.

8

6

 

3

 

7

 

5

60

 

50

 

2

 

1

5

3

 

4

CHECK STOP

(BLUE TO RED)

CHECK STOP

(RED TO BLUE)

4 TEMPERATURE CALIBRATION

Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing upwards.

SET HOT LIMIT STOP

The maximum mixed water temperature is set at 109

F at the factory.

This setting can be changed if desired.

4

Manual background Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.

For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5). Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.

Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards.

Reinstall RED LOCKING DEVICE (5).

ARROW

1

"B"

 

ARROW

"A"

104

109

3

112

2

5

5

OPERATING THE VALVE

1

 

 

If the system is delivering all Hot or all Cold and no mixed water the pipes are probably transposed.

 

 

 

If a temperature over 100 F is desired, pull the RED STOP BUTTON (1) away from the body of the MIXER UNIT and turn the TEMPERATURE KNOB.

This will increase the mixed water temperature up to the maximum limit previously selected in step 4.

100

M968417 REV 1 . 1

Page 2
Image 2
American Standard T050.210 Trim Installation, Transposed Supply Piping Or Back To Back Installation, Set Hot Limit Stop