1 INSTALL TRIM
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
When finished tiling the wall, remove PLASTER GUARD (A)
| and turn off water supply. |
| 10 |
|
Install STEM ADAPTER (1) onto valve stem with ADAPTER |
|
|
| |
| SCREW (2). |
|
|
|
Push CAP (3) over VALVE CARTRIDGE (4). |
|
| A | |
Mount ESCUTCHEON (5) to valve body with SCREWS (6). | 11 |
|
| |
Push DIAL PLATE (7) over CAP (3) and into the four alignment |
|
| ||
|
|
| ||
| holes in ESCUTCHEON (5). |
|
|
|
Remove PIPE CAP (8) and PIPE CAP (9) from shower pipe and tub filler |
|
|
| |
| pipe. | (4) ALIGNMENT |
|
|
Install SHOWER ARM (10), SHOWER HEAD (11) and TUB | HOLES FOR |
|
| |
| FILLER SPOUT (12) by threading onto pipe nipples using teflon | DIAL PLATE | 2 | 1 |
|
| |||
| tape or pipe sealant. |
|
| |
|
| 3 |
| |
Align HANDLE (13, 14) and push onto STEM ADAPTER (1). |
|
| ||
|
|
| ||
| Tighten set screw in HANDLE (13, 14) securley with HEX | 5 |
|
|
| WRENCH (15) supplied. |
|
| |
|
|
|
| |
| 14 | 9 |
|
|
|
|
|
| |
| 13 |
|
|
|
|
|
| 4 |
|
|
| 10 | 12 |
|
|
|
|
|
8
4
11
9
2 TO GAIN ACCESS TO VALVE FOR SERVICING
Remove HANDLE and TRIM. See step one and reverse assembly | HANDLE |
procedure. | and TRIM |
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4)
and pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean
Turn on water supply and see above for installing TRIM and HANDLE. If it still leaks, replace pressure balancing unit
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of
Top flange should