3ADJUST HOT LIMIT STOP

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

TEMPERATURE SETTING NUMBERS

"B"

ADJUSTMENT WHEN WATER IS TOO COLD

PRY RED RING FORWARD AND ROTATE CLOCKWISE

"B"

"A"

"A" ADJUSTMENT WHEN WATER IS TOO HOT

 

 

PRY RED RING FORWARD AND ROTATE

1

0

COUNTER-CLOCKWISE ONE CLICK

2 3

4 5 6

1

"RED RING"- HOT LIMIT SAFETY STOP

4SERVICE

If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:

Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5).

Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.

4

1

2

3

5

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M 9 6 8 6 9 0