IMPORTANT

The vent system must terminate so that proper clearances are maintained as cited in local codes or the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas and Propane Installation Code,

CAN/CSA-B149.1.

Do not terminate the exhaust vent terminal over public area where condensate or vapor can cause nuisance or hazard.

Plan the vent system layout so that proper clearances are maintained from plumbing and wiring.

Vent pipes serving power vented appliances are classified by building codes as "vent connectors". Required clearances from combustible materials must be provided in accordance with information in this manual under LOCATION OF HEATER and CLEARANCES, and with National Fuel Gas Code and local Codes.

IMPORTANT

Plan the layout of the vent system backwards from the vent termination to the appliance.

WARNING

USE ONLY THE VENT TERMINALS SUPPLIED WITH THIS UNIT. TERMINATION OF A VENT SYSTEM WITH A DEVICE OTHER THAN THE SUPPLIED VENT TERMINATIONS WILL AFFECT SYSTEM PERFORMANCE AND RESULT IN A SAFETY HAZARD.

DIRECT VENTING

The air intake provided on the unit contains a mesh screen (see Figure 7) to prevent large particles from entering the unit.

FOR ALL

MODELS

FIGURE 8.

IMPORTANT

WHEN LOCATING THE TERMINALS ON A SIDEWALL, THE FOLLOWING SPECIFICATIONS PERTAINING TO TERMINAL LOCATION MUST BE FOLLOWED.

1.The intake vent terminal and the exhaust vent terminal must terminate on the same exterior wall and must be located at a minimum of 24" (61cm) from the vertical centerline of the exhaust vent terminal (see Figure 9). In colder climates increasing the 24" (61cm) minimum will reduce possibility of frost over from side winds blowing exhaust vapors to the air intake of the direct vent.

2.The horizontal centerline of the intake vent terminal may not be located lower than the horizontal centerline of the exhaust vent terminal (see Figure 9).

FIGURE 7.

WARNING

WHEN THE UNIT IS TO BE SETUP AS A DIRECT VENT, THE MESH SCREEN MUST BE REMOVED. THE INLET VENT PIPE MAY THEN BE GLUED TO THE AIR INTAKE (see Figure 8) PROVIDED ON THE UNIT.

DIRECT VENT TERMINAL INSTALLATION

IMPORTANT

THIS UNIT CONSISTS OF TWO VENT TERMINALS - AN INTAKE VENT TERMINAL AND AN EXHAUST VENT TERMINAL. THE INTAKE VENT TERMINAL IS A 3" 45° PVC ELBOW WITH A DOME MESH WIRE SCREEN AND THE EXHAUST VENT TERMINAL IS A 3" 45°PVC ELBOW WITH A MESH WIRE SCREEN.

NOTE: TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY/COLD AREAS, THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED

INSTALLATION SEQUENCE

For installations in the City of Los Angeles, California Category IV PVC Pipe such as that manufactured by Brownline Pipe Company, must be used as vent pipe material

CAUTION

Vent terminals supplied with the heater must be used.

NOTE: BEFORE BEGINNING INSTALLATION OF ANY VENT PIPE READ THE VENT PIPE MANUFACTURER'S INSTALLATION INSTRUCTIONS.

1.After the points of termination have been determined, use the cover plates as templates to mark the holes for the vent pipes to be inserted through the wall. BEWARE OF CONCEALED WIRING AND PIPING INSIDE OF WALL.

2.If the vent terminals are being installed on the outside of a finished wall, it may be easier to mark both the inside and outside wall. Align the holes by drilling a hole through the center of the template from the inside through to the outside. The template can now be positioned on the outside wall using the drilled holes as a centering point for the template.

3.A) MASONRY SIDE WALLS

Chisel an opening approximately 1/2" (1.3 cm) larger than the marked circle.

B) WOODEN SIDE WALLS

Drill a pilot hole approximately one quarter inch outside of the marked circle. This pilot hole is used as a starting point for a saws-all or sabre saw blade. Cut around the marked circle staying approximately one quarter inch outside of the line. (This will allow the vent pipe to easily slide through the opening. The resulting gap will be covered by the vent terminal cover plates.) Repeat this step on the inside wall if necessary.

4.Cut a length of 3" PVC pipe about 3.5" (8.9 cm) longer than the wall thickness at the opening.

10

Page 10
Image 10
American Water Heater AHCG3/HCG360T120 warranty Direct Venting, Direct Vent Terminal Installation, Installation Sequence

AHCG3/HCG3100T250, AHCG3/HCG360T120 specifications

The American Water Heater AHCG3/HCG360T120 and AHCG3/HCG3100T250 are innovative models designed to meet the diverse needs of residential and commercial water heating. These state-of-the-art water heaters provide exceptional performance, efficiency, and reliability, making them ideal choices for consumers seeking long-lasting solutions for their hot water needs.

Both models are equipped with a robust design and advanced technology, ensuring effective operation and streamlining maintenance. The AHCG3/HCG360T120 has a capacity of 60 gallons, making it suitable for larger households or commercial applications, while the AHCG3/HCG3100T250 has a higher capacity of 100 gallons, providing ample hot water for multiple simultaneous uses.

One of the standout features of these water heaters is their high energy efficiency. Both models are designed to reduce energy consumption, translating to lower utility bills. The units are equipped with environmentally friendly insulation, which minimizes heat loss and maintains the temperature of the stored water longer. This construction not only conserves energy but also ensures consistent hot water delivery.

Innovative heating technology is another characteristic that sets the AHCG3/HCG series apart. These water heaters employ a combination of reliable heating elements and advanced electronics to provide precise temperature control. This technology ensures that users have access to hot water whenever they need it without significant waiting periods.

The American Water Heater AHCG series also emphasizes ease of use and installation. Each unit features user-friendly controls that allow for easy adjustment of temperatures and settings. The compact design ensures they fit comfortably in various spaces, making installation seamless in basements, utility rooms, or garages.

Durability and reliability are key aspects of these water heaters. Made with high-quality materials, they are designed to withstand the rigors of daily use while adhering to strict industry standards. Their robust construction minimizes the risk of leaks and ensures a long operational lifespan.

In summary, the American Water Heater AHCG3/HCG360T120 and AHCG3/HCG3100T250 models combine advanced technology, energy efficiency, and durability. These features make them excellent investments for anyone seeking a dependable hot water solution for their home or business, providing peace of mind and a reliable supply of hot water.