Residential High Efficiency Gas
MODEL | GALLON | ENERGY | BTU INPUT | RECOVERY | FIRST | FOAM |
|
| DIMENSIONS IN INCHES |
|
| DRAFT | SHIPPING | ||
AT 90° | HOUR | THICKNESS |
|
|
|
|
|
|
| HOOD | WEIGHT | ||||
NUMBER | CAPACITY | FACTOR | PER HOUR | A | B | C | D |
| E | F | |||||
RISE | RATING | (INCHES) |
| OUTLET | (LBS) | ||||||||||
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PCG6240T403NOV | 40 | .70 | 40,000 | 43 | 70 GPH | 2 | 20 | 58 |
| 25 | 3 or 4 | 157 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PCG6250T403NOV | 50 | .70 | 40,000 | 43 | 81 GPH | 2 | 22 |
|
| 27 | 3 or 4 | 171 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All dimension in inches.
Recovery capacity based on actual performance tests.
Water Connections – 3/4” on all models.
Not available in LP gas (Propane).
Certified for installations up to 5500 ft. elevations.
|
| 1/2” |
|
|
| DRAFT HOOD |
|
|
| T&P VALVE |
|
|
| A |
|
B | C | D |
|
|
| GAS VALVE | F |
|
| ON/OFF SWITCH | |
|
|
| |
|
| DRAIN VALVE | HOT |
|
| CONNECTION | |
|
|
|
ANODE ROD
COLD
CONNECTION
8”
TOP VIEW
FRONT VIEW
Maximum Hydrostatic Working Pressure: 150 PSI
Flammable Vapor Ignition Resistant Water Heaters
This FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - 4.1 CSA Standards) that deal with the accidental or unintended ignition of flammable vapors outside the water heater, such as those emitted by gasoline.
Residential Gas High Efficiency Water Heater Specification
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______
warranty and a ______
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.
Heaters shall meet or exceed the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of 1992. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a
| Distributed By: |
|
Order Entry and Sales | Warranty and Service | |
500 Princeton Road (FEDEX, UPS) | 500 Princeton Road (FEDEX, UPS) | |
Johnson City, TN | Johnson City, TN | |
P.O. Box 4808 (Mailing) | P.O. Box 1597 (Mailing) | |
Johnson City, TN | Johnson City, TN | |
(800) | (800) | |
FAX (800) | FAX (800) |
NRGSS01010
No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.