INSTALLATION OF VENT SYSTEM, SIDEWALL

With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT

SYSTEM, the through the wall vent terminal in place and the first section of piping, up to first elbow, installed at the blower it is time to complete the

installation of the venting system for the sidewall installation.

GRADE

SNORKEL

*MIN. 12” (30 cm)

ABOVE GRADE OR

*MIN. 12” (30 cm)

ABOVE

ANTICIPATED

SNOW LEVEL

INSTALL A SNORKEL AS SHOWN

HERE ONLY IF NECESSARY TO

ACHIEVE THE 12” MINIMUM

CLEARANCE ABOVE

THE HIGHEST ANTICIPATED

SNOW LEVEL.

FIGURE 20

It is recommended that the completion of the venting system start at the blower assembly and run to the coupling on the inside wall of the vent terminal, Figure18.

The vent system piping should be supported every 5 feet (1.5 m) of vertical run and every 3 feet (91 cm) of horizontal run. Follow vent pipe manufacturer’s instructions for proper joining procedures.

If necessary to achieve the 12” minimum clearance above the highest anticipated snow level, install a snorkel as shown in bottom portion of Figure 20.

NOTE: With the installation of a snorkel it is necessary to use two 90° elbows that shall be considered along with the

additional vent pipe when calculating maximum equivalent feet of venting.

INSTALLATION OF VERTICAL VENT SYSTEM

A proper flashing or “BOOT” should be used to seal the pipe

where it exits the roof. The total vent system should not exceed the equivalent feet of pipe as listed in Table 1.

Provide support for all pipe protruding through the roof. All piping should be properly secured. The vent system piping should be supported

every 5 feet (1.5 m) of vertical run and every 3 feet (91 cm) of horizontal run. Follow vent pipe manufacturer’s instructions for proper

joining procedures.

FIGURE 21

IMPORTANT

The vent system must terminate so that proper clearances are maintained as cited in local codes or the current edition

of the National Fuel Gas Code (ANSI Z223.1) or the Natural Gas and Propane Installation Code (CAN/CSA-B149.1) and as

listed below:

1.Vent Termination must extend a minimum of 12 inches (30 cm) above roof or 12 inches (30 cm) above the anticipated snow level to prevent blockage of the vent termination, as shown in Figures 20 and 21.

23

Page 23
Image 23
American Water Heater VG6250T76NV Series 100 Installation of Vent SYSTEM, Sidewall, Installation of Vertical Vent System

vG6250t76nv, VG6250T76NV Series 100 specifications

The American Water Heater VG6250T76NV, part of the VG6250T76NV Series 100, stands out as a reliable and efficient option for residential water heating needs. This model is designed to offer optimal performance and longevity, making it an ideal investment for any homeowner.

One of the main features of the VG6250T76NV is its impressive capacity. With a 50-gallon tank, it can provide ample hot water for families with multiple bathrooms, ensuring that everyone has enough hot water for showers, laundry, and dishwashing without running out. This feature is particularly beneficial for busy households where hot water demand can be high.

The VG6250T76NV is equipped with a highly efficient gas burner system. This system not only reduces heating times but also enhances energy savings, allowing homeowners to save on their utility bills. The gas burner provides quick recovery rates, meaning that users will not experience long waits for hot water after heavy usage.

Another significant aspect of this water heater is its innovative insulation design. The tank features high-density foam insulation that minimizes heat loss, which helps to maintain water temperature for longer periods. This insulation technique also contributes to overall energy efficiency, making it an environmentally friendly choice.

Safety is also a top priority with the VG6250T76NV. It includes a reliable temperature and pressure relief valve to prevent overheating and potential hazards. Additionally, it is equipped with a built-in safety shut-off feature, ensuring peace of mind for homeowners.

The VG6250T76NV is designed with user-friendliness in mind. It features an adjustable thermostat that allows for easy temperature control, as well as a side-mounted tap for flexible installation options. The unit has a robust construction that ensures durability, with a corrosion-resistant tank that helps extend its lifespan.

With a limited warranty, the American Water Heater VG6250T76NV provides additional assurance of quality and performance. This water heater combines advanced technology, thoughtful design, and efficient operation to deliver a product that meets and exceeds consumer expectations. Overall, the VG6250T76NV Series 100 is an excellent choice for anyone looking to upgrade their home’s hot water supply system.