1073 & 1084 Channel Amplifiers

Dimensions

Dimensions

Stand-alone Modules

Width

mm (inches)

Height

mm (inches)

Depth

mm (inches)

Approx.

Weight

kg (lbs)

1073 Module

45 (1.8)

222 (8.75)

254 (10)

2.5 (5.5)

1084 Module

45 (1.8)

222 (8.75)

254 (10)

2.5 (5.5)

19" Rack Mounting

U

Depth

mm (inches)

Height

mm (inches)

Approx. Weight

kg (lbs)

2 Module Version

3

405 (16)

133 (5.25)

11 (24.2) *

8 Module Version

5

405 (16)

222 (8.75)

30 (66) *

* Fully populated rack

Power Requirements

Rack Units

3U

5U

 

 

 

Rated Voltage

100-230V AC

100-230V AC

 

 

 

Rated Frequency

50-60 Hz

50-60Hz

 

 

 

Rated Current

0.5A Max

0.8A Max

 

 

 

 

 

 

Primary Protection Fuse:

 

 

 

 

 

Operating Voltage

100-230V AC

100-230V AC

 

 

 

Fuse Rating and Type

T0.5A H 250V

T1A H 250V

 

20mm x 5mm CERAMIC

20mm x 5mm CERAMIC

 

 

 

Location

IEC Mains connector

IEC Mains connector

 

 

 

Secondary Protection Fuse:

 

 

 

 

 

Output Voltage

 

24V DC

 

 

 

Fuse Rating and Type

 

T 2.0A L 250V

 

 

20mm x 5mm GLASS

 

 

 

Location

 

F1

 

 

 

Output Voltage

 

48V DC

 

 

 

Fuse Rating and Type

 

T 250mA L 250V

 

 

20mm x 5mm GLASS

 

 

 

Location

 

F2

 

 

 

 

 

Modules

Power

 

 

1073 Module

106mA ±10mA at 24V DC. Negative Earth

 

 

1084 Module

106mA ±10mA at 24V DC. Negative Earth

 

 

 

User Guide Issue 3

Page 3

Page 5
Image 5
AMS 1073, 1084 specifications Dimensions, Power Requirements