1073 & 1084 Channel Amplifiers | Phantom Power |
Mains Supply (rack units)
The 3U rack has a fused, voltage selector IEC mains input connector.
The 5U rack has a free standing AC supply with a fused, voltage selector IEC mains input connector and connects to the rack via a connector and a 1.5 meter cable.
The mains switch on the rear panel of the 3U rack unit is
The CH (chassis) and 0V are linked internally.
DC Power Supply Indicators (rack units)
The red LED on the front panel of both 3U and 5U rack units indicates +24V power healthy when illuminated.
The green LED on the front panel of both 3U and 5U rack units indicates +48V power healthy when illuminated.
Phantom Power
Phantom power can be supplied to each module by pressing the phantom power switch on the front panel of the 3U or 5U rack. The LED in the switch will illuminate confirming that phantom power is supplied.
Output Level Control
Each channel has an independent Output Level Control. The control is
When the Output Control is fully clockwise the output gain is unity. The output is 20dB down with the control in the
User Guide Issue 3 | Page 4 |