EXT Control

8051 5.1 Compressor

User Guide

EXT Control

The EXT buttons provide an insert point in the control voltage signal, after the bias control but before routing back to the channels.

During normal operation the control voltages generated by the sidechain are internally connected to the CV Link switched for routing back to the channels. In EXT mode the control voltage is taken from the rear connector instead of the sidechain outputs, allowing the unit to be slaved from a second 8051 or 33609.

￿There is no EXT Control with 88R(S) console mounted compressors (AM5052 & AM5265).

Pin

Function

 

 

1

0V Reference

 

 

9

CV send, sidechain A

 

 

12

Remote power-on

 

 

5

CV send, sidechain B

 

 

13

CV return, sidechain B

 

 

14

CV return, sidechain A

 

 

15

24V Reference

 

 

Short to pin 12 to pin 1 to take the unit out of standby mode remotely.

CONTROL

 

 

 

 

 

 

 

VOLTAGE I/O

KEY INPUT

INPUT 6

INPUT 5

INPUT 4

INPUT 3

INPUT 2

INPUT 1

 

 

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

WARNING

 

 

 

 

 

 

 

DISCONNECT MAINS LEAD

 

 

 

 

 

 

 

TO ISOLATE UNIT.

 

 

 

 

 

 

 

NO USER SERVICEABLE

CHASSIS INTERNAL

OUTPUT 6

OUTPUT 5

OUTPUT 4

OUTPUT 3

OUTPUT 2

OUTPUT 1

PARTS INSIDE

0V

HAZARDOUS VOLTAGES INSIDE

PLEASE SEE

 

 

 

 

 

 

REFER TO MANUALS

MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE 1.6A A/S CERAMIC

INPUT VOLTAGE 100-250V AC

INPUT FREQUENCY 47-63Hz

Issue 2