AMX AXB-MIDI instruction manual Discharge the static electricity from your body

Models: AXB-MIDI

1 20
Download 20 pages 49.57 Kb
Page 10
Image 10
1.Discharge the static electricity from your body.

Installation

Static electricity can damage electronic circuitry. Before removing the lithium battery from the enclosure, discharge any accumulated static electricity from your body by touching a grounded metal object.

You will need a flat-blade tool (non-conducting) that can be slipped under the lithium battery to pry it up and out of the socket. The location of the Lithium battery on the circuit board is shown in FIG. 7.

rear

Battery/socket

front

FIG. 7 AXB-MIDI circuit card, showing location of battery

1.Discharge the static electricity from your body.

2.Unplug all cables from the AXB-MIDI.

3.Remove the five pan-head screws on the top of the AXB-MIDI enclosure.

4.Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface.

5.Locate the battery on the circuit card.

6.Carefully pry the battery out of its socket and insert the new battery. Write down the next replacement date on a sticker or label by adding 5 years to the replacement date. Then attach it to the bottom of the AXB-MIDI.

7.Plug all cables back into the AXB-MIDI.

8.Place the top portion of the enclosure back onto the bottom portion. Then, refasten the five pan-head screws.

9.Reconnect the cables.

There is a danger of explosion if you replace the battery incorrectly. Replace the battery with the same or equivalent type recommended by the manufacturer. Dispose of used battery according to the manufacturer's instructions. Never recharge, disassemble, or heat the battery above 212°F (100°C). Never solder directly to the battery or expose the contents of the battery to water.

 