AMX specifications NXC-IRS4 FG2023 Specifications, NXC-IRS4 Pinouts, Signals, and Functions

Models: NXC-IRS4

1 2
Download 2 pages 23.64 Kb
Page 1
Image 1
Installation Guide

Installation Guide

NXC-IRS44-Port IR/S Card, 4 IR/S and 4 Inputs

NetLinx Control Cards and NetModules

NetLinx Control Cards can be installed in either the NXF CardFrame, NI-4000, or NetModules. This document provides basic specifications and wiring information for the NetLinx Control cards. For detailed information on the cards, refer to the NetLinx CardFrame, Control Cards, and NetModules Instruction Manual.

NXC-IRS4 4-Port IR/S Control Card

The NXC-IRS4 4-Port IR/S Control Card provides four IR/Serial output control ports with LED status feedback. Each port in the NXC-IRS4 stores programmed commands for IR- or serial-controlled devices.

Specifications

NXC-IRS4 (FG2023) Specifications

Power

110 mA @ +12 VDC power for sensors

 

 

 

Operation:

IR 1-4: 4 IR/Serial control ports

 

Input 1-4: 4 input ports for closure or 0-5 VDC sensing, 200 mA

 

 

Memory

32K of IR memory shared between four ports.

 

 

IR Frequency range

Support of high-frequency carriers up to 1.14 MHz.

 

 

Status LEDs:

Red LED shows IR transmission activity / yellow LED shows input

 

status activity (2 LEDs per channel). LEDs light to indicate ON

 

status:

 

LED 1: Channel 1 Input (yellow)

 

LED 2: Channel 1 IR Out (red)

 

LED 3: Channel 2 Input (yellow)

 

LED 4: Channel 2 IR Out (red)

 

LED 5: Channel 3 Input (yellow)

 

LED 6: Channel 3 IR Out (red)

 

LED 7: Channel 4 Input (yellow)

 

LED 8: Channel 4 IR Out (red)

 

 

 

Connections/wiring:

Two 2-pin 3.5 mm captive-screw terminals

 

• Two CC-NIRC IR Emitters

 

 

 

Models:

NXC-IRS4 4-Port IR/S Card

 

NXM-IRS4 4-Port IR/S NetModule

 

 

DEVICE_ID:

$0108

 

 

 

Pinouts, Signals, and Functions

NXC-IRS4 Pinouts, Signals, and Functions

Pin

SignalFunction

Pin

Signal

Function

 

 

 

 

 

 

1

GND

Signal ground

10

Input #1

Logic input

 

 

 

 

 

 

2

Output #1

IR data

11

Input #2

Logic input

 

 

 

 

 

 

3

GND

Signal ground

12

Input #3

Logic input

 

 

 

 

 

 

4

Output #2

IR data

13

Input #4

Logic input

 

 

 

 

 

 

5

GND

Signal ground

14

Power

+12 VDC

 

 

 

 

 

 

6

Output #3

IR data

15

---------------

no connection

 

 

 

 

 

 

7

GND

Signal ground

16

---------------

no connection

 

 

 

 

 

 

8

Output #4

IR data

17

---------------

no connection

 

 

 

 

 

 

9

GND

Signal ground

18

---------------

no connection

 

 

 

 

 

 

 

 

 

19

---------------

no connection

 

 

 

 

 

 

 

 

 

20

---------------

no connection

 

 

 

 

 

 

NXC-IRS4 Channel Assignments

The IRS4 channel settings listed in the following table set the IR output channels. The NXC-IRS4 can process up to two IR or serial device channel setting commands simultaneously. If more than two device commands are sent simultaneously, only the first two devices receive the commands.

NXC-IRS4 Channel Assignments

Channel Description

1-255

Generates the IR or serial command assigned to that channel.

 

 

1-199

Provides intelligent feedback; if a channel with no IR command is turned on,

 

the card will turn that channel off.

 

Ports 1-4 Generates PUSH and RELEASE statements corresponding to the state of

 

inputs 1 - 4. A contact closure to GND is reported as a PUSH.

 

• The PUSH and RELEASE channel is 255.

 

Channel reporting status is 255.

 

Channel 255 changes are disabled after receipt of the ’PON’ command.

Programming Information

NXC-IRS4 SEND_COMMANDS

CAROFF

Syntax:

Disable the IR carrier

 

SEND_COMMAND <DEV>,"'CAROFF'"

signal until a 'CARON'

Example:

command is received.

 

SEND_COMMAND IR_1,"'CAROFF'"

 

Stops transmitting IR carrier signals to the IR_1 port.

 

 

CARON

Syntax:

Enable the IR carrier

 

SEND_COMMAND <DEV>,"'CARON'"

signals (default).

Example:

 

 

SEND_COMMAND IR_1,"'CARON'"

 

Starts transmitting IR carrier signals to the IR_1 port.

 

 

CH

All channels below 100 are transmitted as two digits. If the IR

Send IR pulses for the

code for ENTER (function #21) is loaded, an Enter will follow

selected a channel.

the number. If the channel is greater than or equal to (>=) 100,

 

then IR function 127 or 20 (whichever exists) is generated for

 

the one hundred digit. Uses 'CTON' and 'CTOF' times for pulse

 

times.

 

Syntax:

 

 

SEND_COMMAND <DEV>,"'CH',<Number>"

 

Channel number = 0 - 199.

 

Example:

 

 

SEND_COMMAND IR_1,"'CH',18"

 

The NXC-IRS4 performs the following:

 

Transmits IR signals for 1 (IR code 11). The transmit time is

 

 

set with the CTON command.

 

Waits until the time set with the CTOF command elapses.

 

Transmits IR signals for 8 (IR code 18).

 

Waits for the time set with the CTOF command elapses. If

 

 

the IR code for Enter (IR code 21) is programmed, the IRS4

 

 

performs the following steps.

 

Transmits IR signals for Enter (IR code 21).

 

Waits for the time set with the CTOF command elapses.

 

 

CP

Syntax:

Halt and Clear all active

 

SEND_COMMAND <DEV>,"'CP',<code>"

or buffered IR com-

Code = IR port's channel value 0 - 252 (253 - 255 reserved).

mands, and then send a

Example:

single IR pulse. Set the

 

SEND_COMMAND IR_1,"'CP',2"

Pulse and Wait times

 

Clears the active/buffered commands and pulses IR_1 port's

with the 'CTON' and

channel 2.

'CTOF' commands.

 

 

 

 

CTOF

This command sets the delay time between pulses generated

Set the duration of the

by the 'CH' or 'XCH' send commands in tenths of seconds.

Off time (no signal)

Syntax:

between IR pulses for

 

SEND_COMMAND <DEV>,"'CTOF',<time>"

channel and IR function

Time = 0 - 255. Given in 1/10ths of a second. Default is 5

transmissions.

(0.5 sec).

Off time settings are

Example:

stored in non-volatile

 

SEND_COMMAND IR_1,"'CTOF',10"

memory.

 

Sets the Off time between each IR pulse to 1 second.

 

 

 

CTON

This command sets the pulse length for each pulse generated

Set the total time of IR

by the 'CH' or 'XCH' send commands in tenths of seconds.

pulses transmitted and is

Syntax:

stored in non-volatile

 

SEND_COMMAND <DEV>,"'CTON',<time>"

memory.

Time= 0 - 255. Given in 1/10ths of a second. Default is 5

 

(0.5 sec).

 

Example:

 

 

SEND_COMMAND IR_1,"'CTON',20"

 

Sets the IR pulse duration to 2 seconds.

 

 

GET MODE

The port responds with: <port #> <mode>,<carrier>,<io link

Poll the IR/Serial port's

channel>.

configuration parame-

Syntax:

ters and report the active

 

SEND_COMMAND <DEV>,"'GET MODE'"

mode settings to the

Example:

device requesting the

 

SEND_COMMAND IR_1,"'GET MODE"

information.

The system could respond with:

 

 

 

PORT 4 IR,CARRIER,IO LINK 0

 

 

IROFF

Syntax:

Halt and Clear all active

 

SEND_COMMAND <DEV>,"'IROFF'"

or buffered IR commands

Example:

being output on the

 

SEND_COMMAND IR_1,"'IROFF"

designated port.

Immediately halts and clears all IR output signals on the IR_1

 

port.

 

 

 

Page 1
Image 1
AMX specifications NXC-IRS4 FG2023 Specifications, NXC-IRS4 Pinouts, Signals, and Functions, NXC-IRS4 SENDCOMMANDS