GROUND POLE INSTALLATION

2³⁄₈” O.D. x 72” LONG

PARTS AND HARDWARE LISTING

PIER FOUNDATIONS

37

72

OVAL END

2³⁄₈" O.D.

1" to 2"

SLOPE FOR WATER RUN OFF

GRADE

36

DEEP

FROST LINE

FOUNDATIONS

37

72

OVAL END

2³⁄₈" O.D.

NOTE:

48" may be

increased, concrete and length of rebar will increase accordingly.

1" to 2"

SLOPE FOR WATER RUN OFF

GRADE

 

48"

 

(SEE NOTE)

 

1-1.5"

 

APPROX.

d

2"

MIN.

 

BELOW

CLAMP

12

SURFACE

 

 

13

 

11

 

9

 

6

 

5

14

 

 

6

d

MIN.

BELOW

DIA.

FROST LINE

 

DIA.

FROST LINE

(4) #3 x 24" MIN. AT 90˚ APART (SEE NOTE)

4

8

7

 

 

PIER FOUNDATIONS

 

 

DEEP FROST LINE FOUNDATIONS

ANT

 

WIND VEL.

 

DIM “d”

 

CONC VOL.

DIM “d”

 

CONC VOL.

 

GROUND POLE

 

 

 

 

 

 

 

80 MPH

 

9”

 

1.5 FT3

7”

 

1.2 FT3

 

 

 

 

90 MPH

 

11”

 

2.2 FT3

7”

 

1.2 FT3

 

Mo. 611652931

90cm

 

100 MPH

 

13”

 

3.0 FT3

8”

 

1.5 FT3

 

 

 

 

110 MPH

 

15”

 

4.0 FT3

10”

 

2.4 FT3

 

SEE NOTE 1

 

 

125 MPH

 

18”

 

5.8 FT3

12”

 

3.5 FT3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80 MPH

 

10”

 

1.8 FT3

7”

 

1.2 FT3

 

Mo. 611652931

1.0M

 

90 MPH

 

13”

 

3.0 FT3

8”

 

1.5 FT3

 

 

 

 

100 MPH

 

15”

 

4.0 FT3

9”

 

1.9 FT3

 

SEE NOTE 2

 

 

108 MPH

 

16”

 

4.6 FT3

10”

 

2.4 FT3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

9

 

7

15

 

10

 

 

Junction Block (9)

FIG. 4.1 - ANTENNA, ANTENNA FEED (LNB) & FEED SUPPORT LEGS

POLE SPECIFICATIONS:

2” SCH 40 2³⁄₈” O.D. x .154 Wall x 72” Long Steel - CM PN 611652931 w/Oval End and Powder Paint Finish.

1.When wind velocity exceeds 108 MPH on the 90cm antenna at heights shown, the ground pole must be a heavy wall pipe as follows: 2” pipe (2³⁄₈” O.D.) Schedule 80 (.218” wall thickness) and purchased locally. Field weld ¹⁄₄ x 1¹⁄₂ x 5 key as shown in Fig. 1.0 to prevent rotation in the concrete or use 3” O.D. ground pole and AZ/EL cap.

2.These charted values based on using Model 611652931 ground pole, 2.375 O.D. x 1.54 wall. When wind velocity exceeds 108 MPH, use 3” O.D. ground pole and AZ/EL cap.

3.Pole and foundation design based on the following criteria: (a) Uniform Building Code Exposure C and 1.5 stability factor, (b) Vertical soil pressure of 2000 pounds per square foot, (c) Lateral soil pressure of 400 pounds per square foot, (d) Concrete compressive strength of 2500 pounds per square inc h in 28 days.

4.CAUTION - The foundation design shown does not represent an appropriate design for any specific locality since soil conditions vary and may not meet design criteria given in Note 1. You should consult a local professional engineer to determine your soil conditions and appropriate foundation.

.21

FIELD WELD

.21

KEY

¹⁄₄ x 1¹⁄₂ x 5

6"

APPROX.

FIG. 1.0

ITEM

DESCRIPTION

4

LEG BOTTOM (90cm)

4

LEG-BOTTOM-FEED (1.0m)

4LEG-BOTTOM-FEED (1.2m)

5REFLECTOR-SMC 1.0m

5REFLECTOR-SMC 1.2m

5REFLECTOR-SMC 90cm

6LEG-SIDE-FEED (1.0m)

6

LEG-SIDE-FEED (1.2m)

6LEG-SIDE-FEED (90cm)

7BOLT-HEX M6 x 30

8WASHER, FLAT ¹⁄₄” x ⁷⁄₈”

9*

BLOCK-JUNCTION

10

WASHER-FLAT ¹⁄₄” x ³⁄₄” O.D.

11*

CLAMP-HALF-JCT.

12*

BOLT HH M6 x 20

13*

WASHER-FLAT M6 x ¹⁄₂” O.D.

14*

KU-FEED ASSY.

15

SCREW-TPG-SPL M6

*Provided in feed assembly.

QTY.

1

1

1

1

1

1

2

2

2

4

2

1

2

1

2

2

1

1

2

11

Page 4
Image 4
Andrew TYPE 900, TYPE 100, TYPE 120 manual Ground Pole Installation, Parts and Hardware Listing