INSTALLATION
This Manual will detail the Installation and Operation of the Filter- Mate system, with notes where the Filtronic II System differs.
Both the Filter Mate and Filtronic II Systems enable the user to safely and efficiently filter the cooking oil or shortening from a fryer in a banked row while the other fryers in that row are still being used. Even though these two Filtration Systems are slightly different in physical dimensions and design, the Installation and Operation is basically the same.
FILTER ELECTRICAL SPECIFICATIONS
Please make sure that your desired filter location has electrical supply factors that are suitable for this product. Requirements are 120 Volts, 60 Hz, 8 Amps,
!
WARNING
!
Electrical Grounding Instructions
This appliance is equipped with a
your protection against shock hazard, and should be plugged
directly into a properly grounded,
cut or remove the grounding prong from this plug.
FILTER UNIT PREPARATION (Refer to Photos On Page 4)
1.Assemble filter envelope to filter screen by sliding the envelope over the filter screen, folding back the open end over the filter screen. Make sure the hole in the filter envelope fits over the fitting on the filter screen.
2.Assemble filter envelope clip over folded back end of envelope and over fitting on filter screen.
3.Attach knurled retaining nut onto fitting on screen, securing the assembly.
4.Attach
5.Place filter unit into the filter tank using the
6.Connect the filter assembly to the pump using the
7.Put the filter tank cover on the tank.
8.Slide the filter tank unit into its location under the fryers or in the filter cabinet.
9.Make the connection from the fryer return line to the filter pump with the
10.Plug the cord on the side of the filter unit into the receptacle on the fryer frame. Make sure that the power switch located on the side or top of filter unit is ON.
3