Anritsu CMA 5000 - UTA specifications Path Analysis, SONET/DSn, Sdh/Pdh, Round Trip Delay

Models: CMA 5000 - UTA

1 14
Download 14 pages 1.93 Kb
Page 11
Image 11
Path Analysis

Path Analysis

Signal Qualification

Power meter

Frequency meter

Errors Analysis

SONET/DSn

 

 

A1/A2, B1, B2, REI-L, B3, REI-P, V5, REI-V, FAW (FAS), SFAW, FPS, MAW, Parity P,

 

Parity CP, F-bit, M-bit, FEBE, CRC-6, PRBS, Word, ERR

 

SDH/PDH

 

 

A1/A2, B1, B2, MS-REI, B3, LP-B3, HP-REI, V5, LP-REI, FAW (FAS), CRC-4, REI (E-bit or

 

 

REBE), PRBS, Word, ERR

Alarms Analysis

SONET/DSn

 

 

LOS, LOF, SEF, TIM-S, AIS-L, RDI-L, AIS-P, LOP-P, TIM-P, PLM-P, UNEQ-P, RDI-P,

 

 

LOM-V, AIS-V, LOP-V, PLM-V, UNEQ-V, RDI-V, TIM-V, RFI-V, OOF, LSF, LOMF, RAI,

 

IDLE, LSS, LPS, AIS

 

SDH/PDH

 

 

LOS, LOF, OOF, RS-TIM, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-PLM, HP-TIM,

 

 

HP-UNEQ, HP-RDI, TU-LOM, TU-AIS, TU-LOP, LP-PLM, LP-UNEQ, LP-TIM, LP-RDI,

 

 

LP-RFI, AIS, RDI, LOMF, LSS, LPS

 

 

 

Pointer Movement Analysis

Pointer value

 

Number of positive and negative pointer movements

 

Number of pointer movement with NDF

 

 

 

Quality Analysis

SONET

 

 

Transmission quality is calculated each second as per GR-253

 

SDH/PDH

 

 

Transmission quality is calculated each second in accordance with recommendations G.826,

 

 

G.828, M.2100, M2101.1, M.2101, M.2110 for performance

 

 

 

Overhead Analysis

J0, J1 and J2 Path Trace messages (ASCII sequence)

 

S1 (synchronization status)

 

C2/V5 (signal label)

 

Complete display of SOH/TOH and POH of the analyzed path channel

 

Capture capacity: 64 consecutive frames

 

 

 

Event Analysis

Alarms and errors event analysis in temporal graphical display with 125 µs resolution

 

 

 

Round Trip Delay

Measurement possible at each path level

Resolution: 100 ns

Range: 0 to 2 sec (depending on path level)

Result: Maximum RTD, minimum RTD, Average RTD and errors/alarms detection

Automatic Protection Switching Measurement

Number of switches

Switch duration (with 125 µs resolution)

K1/K2 capture and interpretation

ISO 9001:2000 certified. ICMA5KUTASTM64-SPEC05-0806-A4. ©2008 Anritsu. All Rights Reserved.

Page 11 of 14