SONET/SDH Overhead Editors

SONET/SDH Overhead Editors

SONET

TOH Editor

All bytes of TOH (STS-1/STS-3) are programmable except B1/B2, H1/H2/H3 and Z0

J0 (Trace Identifier):

oprogrammable 62 bytes ASCII sequence, CRLF added or

oprogrammable 15 bytes ASCII sequence, CRC (E.164) added or o programmable byte

POH Editor (STS)

C2, G1, F2, H4, Z3, Z4, N1

 

J1 (Trace Identifier):

 

 

o programmable 62 bytes ASCII sequence, CRLF added or

 

 

o programmable 15 bytes ASCII sequence, CRC (E.164) added or

 

 

o

programmable byte

 

 

 

POH Editor (VT)

V5, Z6, Z7

 

J2 (Trace Identifier):

 

 

o programmable 62 bytes ASCII sequence, CRLF added or

 

 

o programmable 15 bytes ASCII sequence, CRC (E.164) added or

 

 

o

programmable byte

 

 

 

 

SDH

 

 

 

 

 

 

 

SOH Editor

All bytes of SOH (STM-1) are programmable except B1/B2 and H3

 

J0 (Trace Identifier):

 

 

o programmable 15 bytes ASCII sequence, CRC (E.164) added or

 

 

o programmable 62 bytes ASCII sequence, CRLF added or

 

 

o

programmable byte

 

 

 

POH Editor (VC-4 and VC-3)

C2, G1, F2, H4, F3, K3, N1

 

J1 (Trace Identifier):

 

 

o programmable 15 bytes ASCII sequence, CRC (E.164) added or

 

 

o programmable 62 bytes ASCII sequence, CRLF added or

 

 

o

programmable byte

 

 

 

POH Editor (VC-12)

V5, N2, K4

 

J2 (Trace Identifier):

 

 

o programmable 15 bytes ASCII sequence, CRC (E.164) added or

 

 

o programmable 62 bytes ASCII sequence, CRLF added or

 

 

o

programmable byte

 

 

 

 

 

 

 

 

Error Addition

 

 

 

 

 

 

 

SONET/DSn

A1/A2, B1, B2, REI-L, B3, REI-P, V5, REI-V, FAW (FAS), SFAW, FPS, MAW, Parity P,

 

 

Parity CP, F-bit, M-bit, FEBE, CRC-6, PRBS, Word, transmission errors

 

 

 

SDH/PDH

A1/A2, B1, B2, MS-REI, B3, LP-B3, HP-REI, V5, LP-REI, FAW (FAS), CRC-4, REI (E-bit or

 

 

REBE), PRBS, Word, transmission errors

 

 

 

Error Control

Programmable number or rate

 

 

 

 

ISO 9001:2000 certified. ICMA5KUTASTM64-SPEC05-0806-A4. ©2008 Anritsu. All Rights Reserved.