17
Options

Option 01: Precision frequency reference oscillator

Frequency 10 MHz
Start-up characteristics 5 x 108(7 min. 25˚C, Typical)
Aging rate ±5 x 1010/day (With the frequency at 24 hours after the power is turned on referenced)
Temperature characteristics ±5 x 1010(With the frequency at 0 to 50˚C and 25˚C referenced)

Option 05: Rubidium reference oscillator

Frequency 10 MHz
Start-up characteristics ±1 x 109/7 min. (with frequency one hour after the power is turned on referenced)
Aging rate ±1 x 1010/month (with frequency one hour after the power is turned on referenced)
Temperature characteristics ±1 x 109(with frequency at 0 to 45˚C and 25˚C referenced)
Accessories J1066 coaxial code 0.15 m (BNC211-LP4)

Option 09: Ethernet interface

Function Control with external controller (except for power switch)
Connector 10BASE-T

Option 18: I/Q unbalanced input

Connector BNC
Impedance Selectable between 1 M(parallel capacity <100 pF) and 50
Input level range Differential voltage range: 0.1 to 1 Vp-p (at input terminal)
Changeable between DC connection and AC connection

Option 02: Narrow resolution bandwidths (FFT)

Setting range: 1 Hz to 1 kHz (1, 3 sequence)
Resolution bandwidth Bandwidth accuracy: ±10% (RBW = 30, 300 Hz)
±10% Typical (RBW = 1, 3, 10, 100, 1 kHz)
RBW selectivity (60 dB: 3 dB): 5:1
RBW switching uncertainty: ±0.5 dB
Span setting Minimum setting span: 100 Hz
When RBW is 1 Hz, RF ATT is 0 dB
146.5 dBm + 1.5f [GHz] dB Typical(1 MHz to 2.5 GHz, band 0)
142.5 dBm + 1.5f [GHz] dB Typical(2.5 to 3.2 GHz, band 0)
Average noise level display 137.5 dBm Typical (3.15 to 7.9 GHz, band 1)
135.5 dBm Typical (7.8 to 15.3 GHz, band 2)
125.5 dBm Typical (15.2 to 30 GHz, band 4)

Option 04: Digital resolution bandwidth

Setting range: 10 Hz to 1 MHz (1, 3 sequence)
Bandwidth accuracy: ±10% (RBW 100 Hz)
±10% Typical (RBW 30 Hz)
Resolution bandwidth Bandwidth selectivity (60 dB: 3 dB):
5:1 (RBW 100 Hz)
5:1 Typical (RBW 30 Hz)
RBW switching uncertainty: ±0.5 dB
Detection mode NORMAL, POSITIVE PEAK, NEGATIVE PEAK, SAMPLE, RMS
RMS: displays root-mean-square value of average power between sample points
When RBW is 10 Hz, RF ATT is 0 dB
136.5 dBm + f [GHz] dB Typical (1 MHz to 2.5 GHz, band 0)
132.5 dBm + f [GHz] dB Typical (2.5 to 3.2 GHz, band 0)
Average noise level 127.5 dBm Typical (3.15 to 7.9 GHz, band 1)
125.5 dBm Typical (7.8 to 15.3 GHz, band 2)
115.5 dBm Typical (15.2 to 30 GHz, band 4)