caused by transportation. In the event that the unit's housing or cable is damaged, do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance.

Setup

Remove all packing materials from shipping box. Check that all foam and plastic padding is removed.

Place Fazer on a flat surface and remove Fazer liquid tank cap.

Pour Antari Fog Liquid into the liquid tank, being careful not to exceed the maximum fluid level. DO NOT OVERFILL. Use only ANTARI Fog Liquid or other dealer-recommended high-quality Fog fluid . Any other types of fluid can damage the unit. When the container is full, place the cap back on the liquid tank and tighten.

Your Fazer can only be operated by connecting the Z-6 remote control into the remote control slot in the back of the machine.

Operation

Plug the remote control cord into the slot marked remote control on the back of the Fazer machine. Plug the power cord into a grounded electrical outlet.

Turn on the power switch located on the back of the Fazer machine.

The red light on the remote control will turn on once the machine is plugged into a power outlet and the on/off switch is turned on.

Once the red light comes on the machine must warm-up. This period varies depending on conditions but should not take more than 10 minutes under any circumstances.

The green light on the remote control will turn on once the machine is ready to produce haze. When the green light turns on, the machine may be operated using the remote control.

The Z-300II Fazer is controlled via the Z-6 remote control. Please refer to the section titled Remote Control Operation for detailed instruction on the various functions available.

Prior to the green light turning on the machine will not haze and the functions will not respond.

The Z-300II is equipped with a low fluid sensor. When the fluid is not low the light on the back of the machine is green and will flash on and off continuously. When the fluid is low the light will turn red. When the light is red add fluid to the Fazer immediately.

When the Fazer does not have any liquid in the machine the PC board will shut off the pump so that the machine will not be damaged. The pump will remain off until fluid is added to the machine.

Important: Always monitor tank fluid level during operation. Even with the low level sensor, the Z-300II Fazer machine can suffer damage when run without fluid. If the machine does not function after having been run without fluid please contact your Antari dealer for service.

If you experience low output, mechanical noise or no output at all, unplug immediately.

Check fluid level, the external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the unit in again. If Fazer does not function after 30 seconds, discontinue operation or permanent damage to the unit may result. Return the machine to your ANTARI dealer. Always drain tank before mailing or transporting this unit.

Remote Control Operation

Z-6:10 meter wired multi-function remote controller with 5-pin plug for ANTARI Fazer Z-300II model.

The interval knob adjusts the time between discharges when the timer function is engaged. The range is from 10 seconds ~ 250 seconds.

The second knob, labeled volume, controls the volume of haze produced. The range is from 0% ~ 100% of maximum output.

The yellow TIMER button controls the timer function. Depress the button to activate. When activated the yellow light will turn on. Adjusting the interval knob will determine the time between haze output (10 ~ 250 seconds). The duration of output is set at 15 seconds. The volume can be adjusted using the volume knob to control the amount of haze produced.

The red CONTINUOUS button sets the machine to constant haze production. To activate this function, depress the red button. The volume knob can be used to regulate the volume of the steady stream of haze produced.