caused by transportation. In the event that the unit's housing or cable is damaged, do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance.
Setup
Remove all packing materials from shipping box. Check that all foam and plastic padding is removed.
Place Fazer on a flat surface and remove Fazer liquid tank cap.
Pour Antari Fog Liquid into the liquid tank, being careful not to exceed the maximum fluid level. DO NOT OVERFILL. Use only ANTARI Fog Liquid or other
Your Fazer can only be operated by connecting the
Operation
Plug the remote control cord into the slot marked remote control on the back of the Fazer machine. Plug the power cord into a grounded electrical outlet.
Turn on the power switch located on the back of the Fazer machine.
The red light on the remote control will turn on once the machine is plugged into a power outlet and the on/off switch is turned on.
Once the red light comes on the machine must
The green light on the remote control will turn on once the machine is ready to produce haze. When the green light turns on, the machine may be operated using the remote control.
The
Prior to the green light turning on the machine will not haze and the functions will not respond.
The
When the Fazer does not have any liquid in the machine the PC board will shut off the pump so that the machine will not be damaged. The pump will remain off until fluid is added to the machine.
Important: Always monitor tank fluid level during operation. Even with the low level sensor, the
If you experience low output, mechanical noise or no output at all, unplug immediately.
Check fluid level, the external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the unit in again. If Fazer does not function after 30 seconds, discontinue operation or permanent damage to the unit may result. Return the machine to your ANTARI dealer. Always drain tank before mailing or transporting this unit.
Remote Control Operation
The interval knob adjusts the time between discharges when the timer function is engaged. The range is from 10 seconds ~ 250 seconds.
The second knob, labeled volume, controls the volume of haze produced. The range is from 0% ~ 100% of maximum output.
The yellow TIMER button controls the timer function. Depress the button to activate. When activated the yellow light will turn on. Adjusting the interval knob will determine the time between haze output (10 ~ 250 seconds). The duration of output is set at 15 seconds. The volume can be adjusted using the volume knob to control the amount of haze produced.
The red CONTINUOUS button sets the machine to constant haze production. To activate this function, depress the red button. The volume knob can be used to regulate the volume of the steady stream of haze produced.