Antari Lighting and Effects Z-350 Status Messages, Fuse Replacing, Status LED, Indication

Models: Z-350

1 36
Download 36 pages 55.49 Kb
Page 8
Image 8
Fuse Replacing

Fuse Replacing

Disconnect AC power before replacing fuse. Only replace fuse with same type and rating.

Step 1: Disconnect power cord from supply.

Step 2: Use a flat-head screwdriver to release fuse holder.

Step 3: Replace fuse with exact same type and rating as indicated below.

Step 4: Reinsert fuse holder.

Fuse

100V = T6.3A 250V

110 – 120V = T7A 250V

220 – 240V = T4A 250V

Status Messages

Status LED

Indication

 

 

Flashing Green

Machine is heating up

 

 

Flashing Green (3 seconds)

Self Cleaning

 

 

Solid Green

Machine ready for operation

 

 

Flashing Amber

Producing haze

 

 

Solid Amber

DMX signal received

 

 

Solid Red

Heater is overheating, machine can

 

not be operated

 

 

Flashing Red

Liquid detected backflow to air pump

 

 

Flashing Red/Green

Machine cannot heat up

 

 

8

Page 8
Image 8