User Configurable Items
User Configurable Items
UPS settings
Settings are adjusted through PowerChute software or optional Network Management Card.
Function | Factory | User Selectable | Description | |||
Default | Choices | |||||
|
| |||||
|
|
|
|
| ||
Automatic | Every 14 days | • Every 7 days |
| Set the interval at which the UPS will execute a | ||
(336 hours) | (168 hours) |
|
| |||
|
| • On start up only |
| |||
|
| • No |
|
|
| |
|
|
|
| |||
UPS ID | UPS_IDEN | Up to eight characters | Uniquely identify the UPS (i.e. server name or | |||
|
| (alphanumeric) |
| location) for network management purposes. | ||
|
|
|
|
|
| |
Date of Last | Manufacture | mm/dd/yy |
|
| Reset this date when you replace the battery | |
Battery | Date |
|
|
| module. | |
Replacement |
|
|
|
|
| |
|
|
|
|
|
| |
Minimum Capacity | 0 percent | • 0% | • | 60% | Specify the percentage to which batteries will | |
Before Return from |
| • 15% | • | 75% | be charged following a low battery shutdown | |
Shutdown |
| • 30% | • | 90% | before powering connected equipment. | |
|
| • 45% |
|
|
| |
|
|
|
|
| ||
Voltage Sensitivity | High sensitivity | High sensitivity |
| The UPS detects and reacts to line voltage | ||
|
| Medium sensitivity | distortions by transferring to battery operation | |||
|
| to protect the connected equipment. | ||||
|
| Low sensitivity |
| |||
|
|
| In situations of poor power quality, the UPS | |||
|
|
|
|
| ||
|
|
|
|
| may frequently transfer to battery operation. If | |
|
|
|
|
| the connected equipment can operate normally | |
|
|
|
|
| under such conditions, reduce the sensitivity | |
|
|
|
|
| setting to conserve battery capacity and service | |
|
|
|
|
| life. | |
|
|
|
|
|
| |
Alarm Delay | Enable | • Enable |
|
| Mute ongoing alarms or disable all alarms | |
Control |
| • Mute |
|
| permanently. | |
|
| • Disable |
|
|
| |
|
|
|
|
|
| |
Shutdown Delay | 90 seconds | • 0 s | • | 360 s | Set the interval between the time when the UPS | |
|
| • 90 s | • | 450 s | receives a shutdown command and actual | |
|
| • 180 s | • | 540 s | shutdown. | |
|
| • 270 s | • | 630 s |
| |
|
|
|
|
|
|
8