Connect the equipment

Battery Backup and Surge Protected outlets

When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the Back-UPS.

Connect equipment such as printers, fax machines, scanners, or other peripherals that do not need battery backup power to the Surge Protection Only outlets. These outlets provide full-time protection from surges even if the Back-UPS is switched OFF.

Master and Controlled outlets

To conserve electricity, when the device connected to Master Outlet goes into Sleep or Standby mode, or turns Off, the Controlled device(s) will shut down as well, saving electricity.

Connect a master device, such as a desktop computer or audio/visual receiver to the Master outlet. Connect peripheral devices such as a printer, speakers, or a scanner to the Controlled outlets.

bu126a

USB and Serial Data port To use PowerChute Personal Edition, connect the supplied USB software cable or serial cable (available separately).

Ground screw

Connect the ground lead of additional surge suppression devices such as network and data line

 

surge protectors.

Building Wiring Fault

If this indicator is illuminated, there is a problem with the wiring in the building. Contact an

indicator

electrician immediately and do not use the Back-UPS.

Surge Protected outlets, These outlets are protected from electrical surges, and will disconnect from utility power during

controlled by the Master a power outage, or if the Master device goes into Sleep or Standby mode. outlet

Surge Protected outlets These outlets provide full-time protection from surges, even if the Back-UPS is off. Connect equipment such as printers and scanners that do not require battery backup protection.

Battery Backup outlets with During a power outage or other utility problems, the Battery Backup outlets receive power for a

Surge Protection

limited time from the Back-UPS. Connect critical equipment such as desktop computer,

 

computer monitor, modem or other data sensitive devices into these outlets.

Battery Backup outlets with These outlets will supply battery power to the connected equipment during a power outage. Surge Protection, controlled Power will be disconnected to these outlets if the Master device goes into Sleep or Standby

by the Master outlet

mode. Connect equipment such as a computer monitor to these outlets.

 

 

Master outlet

Connect the master device to this outlet, in most scenarios, this will be the main computer.

In & Out Ethernet surge- Use an Ethernet cable to connect a cable modem to the IN port, and connect a computer to the

protected ports

OUT port.

Co-axial ports with surge Connect a cable modem or other equipment with coaxial jacks. protection

2

Back-UPS Pro 1000 Installation and Operation

Page 2
Image 2
APC BR1000G manual Connect the equipment, Battery Backup and Surge Protected outlets, Master and Controlled outlets