APC UPB50 G. Specifications, H. Troubleshooting, I. Recycling, Storage, and Battery Life

Models: UPB50

1 2
Download 2 pages 48.97 Kb
Page 2
Image 2
G. Specifications

G. Specifications

Item

Specification

 

 

 

Capacity

53

Watt-hours

 

 

 

Output Power

70

Watts Maximum Continuous Power

 

80

Watts Peak Power (short duration)

 

 

Output Voltage

= 16V, 4.4A

 

•• = 19V, 3.6A

Input Power Source

OEM notebook power adapter

 

APC Universal Power Adapter

 

 

Charge Time

Recharges to 100% in 3 hours

 

 

Size (H x W x D)

8.66” x 2.76” x 0.87”

 

(220mm x 70mm x 22mm)

 

 

Weight

0.95 lbs (432 g): battery only

 

1.16 lbs (525 g): battery, power cable, one plug and one jack

 

 

Environmental Storage

-4 ~ 140oF (-20 ~ 60oC)

Operation

32

~ 104oF (0 ~ 40oC)

Agency Approvals

TUV / GS, cUL, FCC, CE, C-tick, VCCI

 

Note:

 

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful

 

interference, and (2) This device must accept any interference received, including interference which may cause undesired operation.

 

 

 

H. Troubleshooting

Problem

Possible Cause

Solution

 

 

 

The UPB50 is not charging the

Notebook AC adapter output

Check the voltage rating from the system label on the notebook or

notebook when the AC adapter is

voltage does not match the output

power adapter. Slide the output voltage selector switch to the

connected to the UPB50.

voltage setting on the output

corresponding voltage. Press the Status button for 1~3 seconds and

 

voltage selector switch.

then release. The LED indicators will illuminate and the battery will

 

 

resume power output.

 

 

 

 

The UPB50 has automatically shut

Remove the UPB50 from the enclosed area, and let it cool for a few

 

down due to abnormally high

minutes. Press the Status button for 1~3 second(s) and then release.

 

temperature.

The unit will recover from thermal protection mode.

 

 

 

 

The notebook being used is

The UPB50 is designed to deliver 70 Watts of continuous output

 

drawing more than 70W from the

power. Perform one of the following to resume the UPB50 power

 

UPB50.

output:

 

 

1. Fully charge the notebook internal battery using the adapter

 

 

provided with the notebook; connect the UPB50 to the notebook.

 

 

OR:

 

 

2. Change the power settings on the notebook to conserve battery

 

 

power.

 

 

 

When not connected to a

When the UPB50 has been stored

Press the Status button for 1~3 second(s) and then release. The

notebook computer, UPB50 does

or has not been connected to a

Status indicators will illuminate and the battery will resume power

not provide power (LED indicators

notebook computer for 15 minutes

output. If no indicators are lit, charge the UPB50.

do not illuminate).

or more, it will enter Sleep Mode

 

 

status.

 

 

 

 

1Actual runtimes vary according to notebook model and power setting; please refer to Runtime Chart.

I. Recycling, Storage, and Battery Life

The UPB50 should be disposed of properly. Please do not incinerate or dispose of in trash receptacles. For more information about APC's battery recycling program, visit: mobilecomputing.apc.com.

For best results, do not store the UPB50 where there is excessive heat or cold, as such environments can damage the battery pack and reduce battery life. If storing the UPB50 for an extended period, completely discharge and recharge the unit before the next use.

To completely discharge: Attach the UPB50 to a notebook and wait until all LED indicators are off during use.

To completely charge: Attach any compatible notebook power adapter to the UPB50 and continue charging it until all Status indicators are extinguished.

For best results, the UPB50 should be completely discharged and recharged once every 3 months. This will condition the cells inside the battery and ensure the UPB50 delivers the most capacity available.

J. Limited Warranty

APC warrants its products to be free from defects in materials and workmanship under normal use and service for one (1) year from the date of purchase for the original purchaser. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty, you must obtain a Returned Material Authorization (RMA) number from APC or an APC Service Center with transportation charges prepaid. It must be accompanied by a brief description of the problem and proof of date and place of purchase. This warranty applies only to the original purchaser.

K. Contact Information

American Power Conversion 132 Fairgrounds Rd

West Kingston, RI 02892, USA

Toll Free: 800.800.4APC (800.800.4272)

Toll: (1) 401.789.5735

Fax: (1) 401.789.3710

Internet: http://www.apc.com

Copyright © 2006. American Power Conversion. All rights reserved.

APC is a registered trademark of American Power Conversion.

All other copyrights are the property of their respective owners.

Specifications are subject to change without notice.

Part #: 990-2475

Page 2
Image 2
APC UPB50 user manual G. Specifications, H. Troubleshooting, I. Recycling, Storage, and Battery Life, J. Limited Warranty