13
SETUp & TESTINg
System setting Setting range, default in bold
00Equipmenttype(8466,8448)(Set by Sw1) 0:heat/cool
1:heatpump
01 Temperature scale 0 : fahrenheit
1:Celsius
02 Fan control in heating 0 : gas or oil furnace (Equipment controls fan)
1:Electric(Thermostatcontrolsfan)
03 Offset temperature for internal sensor 0° : No offset applied
–4°Fto+4°F(–2°Cto+2°C)
04Automode 0 : Auto mode is disabled
1:Automodeisenabled
05 Outdoor temperature sensor 0 : No outdoor temperature sensor attached
1:Outdoortemperaturesensorattached
06Compressorminimumofftime 5 minutes
1 to 5 minutes in 1 minute steps
07 Heating minimum off time 2 minutes
1 to 5 minutes
08Equipmentminimumontime 2 minutes
1 to 5 minutes
SYSTEm SETUp INSTRUCTIONS (CONTINUED)