READ REVERSE SIDE FIRST! | – TOP – | READ REVERSE SIDE FIRST! |
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION
FURNISHED ITEMS | Figure 1 |
| |
24 VAC Transformer |
|
Digital Humidifier Control |
|
(Model 700 only) |
|
Manual Humidifier Control |
|
(Model 700M only) |
|
Humidifier Control |
|
Installation Instructions |
|
Saddle Valve |
|
Humidifier Installation Template |
|
ITEMS NOT FURNISHED |
|
Mounting screws |
|
(sheet metal screws) |
|
Water supply line (1 ⁄4” copper) |
|
Drain line (1 ⁄2” I.D. hose) |
|
Low voltage wire |
|
Model 50 Current Sensing Relay |
|
(if required) |
Figure 2
Figure 3 |
Figure 4 |
1.Detach the cover assembly by lifting the latch at the bottom. Remove the Water Panel® evaporator assembly by grasping at top and tipping out. See Figure 1.
2.Position template on supply plenum. Make sure template is level. Allow clearance for drain line and for servicing. See “Installation Options” on opposite side for position relative to cooling coil.
Trace template outline. Cut
3.Position base (2) in duct opening
4.Rotate swing locks to secure base to duct. See Figure 3. Fasten base to duct using 4 sheet metal screws in holes provided.
PARTS LIST
5.Insert Water Panel Evaporator assembly into base. Make sure bottom of scale control insert (5) is over drain opening. Snap top of evaporator assembly into base.
6.Control installation and wiring.
Disconnect electrical power to furnace before wiring control. In order for humidifier to operate, furnace must be on and RH must be below
MANUAL HUMIDIFIER CONTROL, MODEL 700M:
Manual Control can be mounted in return duct or on wall in living space. Knob and cover must be removed to mount control. See wiring diagram for 24V control connections.
• For return duct mounting, position |
template in convenient location on duct. |
Avoid injury from sharp edges when |
cutting opening. Make sure foam |
gasket is in place and secure control to |
duct using 2 screws in holes provided. |
• For |
will not be affected by drafts or heat |
7. Humidifier will function with cold, |
hot, softened or unsoftened water. |
Hot water (140°F max) is strongly |
recommended to provide maximum |
evaporative capacity. Saddle valve |
provided may be used to tap into water |
supply. See installation instructions on |
saddle valve package. Saddle valve is |
designed to be fully opened or closed. |
Do not use to regulate flow. |
8. Run 1/4” copper tubing from saddle |
valve to solenoid valve. |
TO PREVENT LEAKING. See Figure 4. |
9. INSTALL DRAIN IN ACCORDANCE |
WITH LOCAL CODES. Run 1/2” I.D. hose |
15
2
5
14
7 |
|
|
17 | 1. Front Cover | 10. Motor Mount Gasket |
| 2. Base | 11. Control Relay |
16 | 3. Orifice Plate | 12. Power Cord |
| 4. Motor Mount Bridge | 13. Strain Relief Bushing |
| 5. Scale Control Insert | 14. Solenoid Valve |
6 | 6. Water Panel Evaporator | 15. Connector Plug |
| ||
| 7. Water Distribution Tray | 16. Feed Tube |
3 | 8. Fan Blade | 17. Nozzle |
| 9. Motor | 18. Relay Connector Plug |
8
4
18
10
9
13 |
|
12 | 11 |
|
sources. Remove and discard foam |
gasket and secure control over wire |
access opening using screws & |
anchors provided. |
DIGITAL HUMIDIFIER CONTROL, MODEL 700:
•Select location for control on return duct. Drill 3/4” hole for sensor. Knob and cover must be removed to mount control. Place control on duct with RH sensor extending into duct opening. Make sure gasket is in place around sensor cage. Secure control to duct using 2 screws in openings provided.
•See wiring diagrams on template and control instructions for 24 V control connections.
from drain spud to floor drain. Make |
sure drain has constant downward |
slope and is not kinked. Do not over- |
tighten hose clamp onto drain spud. Do |
not use solvent adhesive on drain spud. |
10. Check humidifier operation. Open |
saddle valve and turn control to highest |
setting. Turn on furnace. Allow |
humidifier to run until water flows from |
drain. Make sure all electrical |
connections are secure and all |
plumbing connections are |
Set control to proper setting. |
NOTE: BEFORE LEAVING THE JOB SITE, MAKE SURE:
1.Saddle valve is fully open.2.All plumbing connections are watertight.3.Humidifier functions properly.1
TEMPLATE MUST BE LEVEL |
IMPORTANT!Be sure owner’smanual containinginstructionsfor operation and warranty information is given to owner in order to avoid unnecessary calls. Warranty is voidunless humidifieris installedby qualified heating andairconditioning contractor due to possiblemisapplication of product.