II. OPERATING INSTRUCTIONS – 400, 600 & 700

There are 2 possible modes of operation of your Aprilaire Humidifier Control – Automatic and Manual. An explanation of both modes follows:

Automatic Mode: (Manual Mode-see pg 6)

Your Aprilaire Humidifier Control is installed in the cold air return duct. During the first heating season, your Humidifier Control needs to be set initially to match your home’s condition. Please follow these steps when adjusting your control (refer to Figure A).

1.Turn the dial setting knob to “5,” which is within the normal range. During the next 24-48 hours it may be necessary to adjust the dial for more or less humidity, depending on your personal comfort and home’s requirements. Refer to the “Operation Guide” (Table 1).

2.During the coldest portion of the first heating season, minor adjustments may be necessary. This is dependent upon your homes’ construction, refer to the “Operation Guide” (Table 1).

TABLE 1 – Operation Guide

Condition

Solution

Condensation on windows

Reduce the setting on the control dial

 

by 1 increment.

Lack of humidity

Increase the setting on the control dial

 

by 1 increment.

Humidifier does not operate

Turn dial to “Test/Reset.” Make certain

 

furnace is operating in heat mode.

 

If unit still doesn’t operate, consult

 

a heating contractor.

 

 

Humidifier won’t shut off

Turn dial to “Off.” If unit continues to

 

operate, consult a heating contractor.

 

 

Test mode

System operation is checked by setting

 

the knob to “Test/Reset.” Make certain

 

furnace blower is operating and furnace

 

is calling for heat. Humidifier will

 

operate for one minute. Be sure to turn

 

the control knob back to the normal

 

setting after checking humidifier

 

operation.

Reset water panel change

Turn the control knob to the

indicator

“Test/Reset” position until the “Change

 

Water Panel” light blinks to reset the

 

water panel change indicator timer.

 

(Blower must be operating and furnace

 

calling for heat.) Be sure to turn the

 

control knob back to the normal setting

 

after resetting the timer.

 

 