MODEL 550
MAINTENANCE INSTRUCTIONS for
APRILAIRE HUMIDIFIER MODEL 550
CAUTION! Sudden operation may cause personal injury or property damage. Turn Humidistat to “off” or lowest setting before servicing.
3 | 5 |
| 6 | 4 |
1 |
|
|
| |
|
| 8 |
| |
|
|
|
| |
7 |
|
| 1. | Front Cover |
|
|
| 2. Feed Tube | |
|
|
| 3. | Nozzle |
|
|
| 4. Water Panel | |
|
|
|
| Evaporative |
|
|
|
| Assembly |
|
|
| 5. | Distribution Tray |
2 |
| 9 | 6. | ”V” Notches |
| 7. Water Panel | |||
|
| |||
|
|
| 8. | Scale Control Insert |
|
|
| 9. Drain Hose |
1.Note Humidistat setting and turn dial to the “OFF” position.
2.At the side of the unit opposite the airflow duct pull front cover (1) off holding with both hands and set aside.
3.Carefully pull the plastic feed tube (2) out of the nozzle (3) at the top of the Water Panel evaporative assembly (4). Pull this assembly out by grasping at top and tipping out.
4.Remove the distribution tray (5) from the Water Panel evaporative assembly by unsnapping the plastic ends of the Scale Control Insert (8), from the tabs at the end of the tray. Lightly scrape any calcium deposits out of the “V” notches (6), but do not scrape the granular coating from the bottom of the tray. This textured surface helps ensure even water flow for maximum performance. If the granular coating has been removed, place several drops of liquid dish soap on the distribution tray and clean thoroughly. This will only need to be done once.
5.Slide the Water Panel evaporator (7) out from the Scale Control Insert (8). Clean the insert frame by twisting and flexing it to loosen the calcium deposits, or use a putty knife. Inspect the Water Panel evaporator (Stock No. 10 for Model 550) and substitute a new one if necessary. Slide the pad back into the insert frame with color mark up and snap the distributor tray back into place.
6.
7.Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting.
8.Turn up Humidistat and check unit operation.