Bunn CDBC, CEZF TROUBLESHOOTING cont REFILL CIRCUIT cont PROBLEM, Probable Cause, Remedy

Models: CEZF CDBC

1 34
Download 34 pages 50.46 Kb
Page 12
Image 12
TROUBLESHOOTING (cont.)
29253 111103

TROUBLESHOOTING (cont.)

REFILL CIRCUIT (cont.)

PROBLEM

Fill or refill does not shut "OFF" (ON/ OFF Switch "ON") (cont)

Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF")

PROBABLE CAUSE

2a. Water Level Probe Sensing System (CDBC-APS/TS/TSR)

2b. Water Level Probe Sensing Sys- tem (CEZ-APS/TC/TS/TSR)

3.Refill valve or control board (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

4.Water is too conductive for proper operation when using the factory setting of sensing threshold. (CDBC- APS/TC/TS/TSR)

1.Refill valve or control board (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

Page 12

REMEDY

A)Disconnect the brewer from the power source. Disconnect the J3 connector from the control board. Check for continuity from the nut on top of the level probe to pin 1 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grommet. Check for continuity from the outside surface of the temperature probe and pin 4 of the plug, continuity should be present. Connect the J3 plug to the control board and proceed to step 3.

B)Disconnect the brewer from the power source. Disconnect the J5 connector from the control board. Check for continuity from the nut on top of the level probe to pin 5 of the plug, continuity should be present. Pull the temperature probe up about an inch from the grom- met. Check for continuity from the outside surface of the temperature probe and pin 2 of the plug, conti- nuity should be present. Connect the J5 plug to the control board and proceed to step 3.

Press ON/OFF switch to "ON" (Indi- cator lamp should be lit). If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow stops, replace the control board. If water flow does not stop, repair or replace the refill solenoid. (See page 30)

Reset the Water Sensing Threshold Adjustment Procedures on page 9.

If water continuously flows out of air vent tube, disconnect the brewer from the power source. If water flow does not stop, repair or replace the refill solenoid. If the valve closes when power is removed, replace the control board. (See pages 21 & 22)