TROUBLESHOOTING (cont.)

TROUBLESHOOTING (cont.)

REFILL CIRCUIT

PROBLEM

Will not fill or refill

Fill or refill does not shut "OFF" (ON/OFF Switch "ON")

PROBABLE CAUSE

1.Power off to brewer (CDBC-APS/ TC/TS/TSR & CEZ-APS/TS/TSR)

2.Water shut off (CDBC-APS/TC/ TS/TSR & CEZ-APS/TS/TSR)

3.Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR)

4.ON/OFF Switch (CDBC-APS/TC/ TS/TSR & CEZ-APS/TS/TSR)

5.Lime build up on Probe (CDBC- APS/TC/TS/TSR & CEZ-APS/TS/ TSR)

6.Refill Valve or Control Board (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

7.Water is too conductive for proper operation when using the factory setting of sensing threshold. (CDBC- APS/TC/TS/TSR)

1.Lime build up on probe (CDBC- APS/TC/TS/TSR & CEZ-APS/TS/ TSR)

REMEDY

Press ON/OFF switch on control panel to determine if power is ON.

Make sure water is ON.

Brewer has shut down due to malfunction (See Diagnostic Chart in manual, Page 19, or under top lid of brewer).

Make sure ON/OFF Switch is "ON" and indicator is lit.

Remove the Probe and check for lime deposit on tip. Clean and reinstall.

Disconnect the brewer from the power source and remove wires from refill valve coil. Check for con- tinuity across the terminals of the solenoid coil. If continuity is not present, replace the refill valve (See page 30). If continuity is present, the valve may be stuck closed. Shut water off to brewer. Set the ON/OFF switch to the "OFF" position. Open the faucet and drain water down in the tank until flow stops or slows to a trickle. Attach a voltmeter to the terminals of the refill solenoid. Con- nect the brewer to the power source. Press the switch "ON". Within five seconds, voltage should be present at the solenoid terminals. If voltage is not present, refer to the wiring diagrams and check the wiring har- ness.

Reset the Water Sensing Thresh- old Adjustment Procedures on page 9.

Remove Probe and check for lime deposits on tip. Clean and reinstall.

Page 11

29253 111103

 

Page 11
Image 11