Bunn CEZF, CDBC TROUBLESHOOTING cont BREWING CIRCUIT cont PROBLEM, Probable Cause, Remedy

Models: CEZF CDBC

1 34
Download 34 pages 50.46 Kb
Page 17
Image 17
TROUBLESHOOTING (cont.)

TROUBLESHOOTING (cont.)

BREWING CIRCUIT (cont.)

PROBLEM

Brew cycle will not start (cont.)

PROBABLE CAUSE

8.Control board or dispense valve (CDBC-APS/TC/TS/TSR & CEZ- APS/TS/TSR)

REMEDY

If the start switch (CEZ-APS/TS/ TSR) or switch panel (CDBC-APS/ TC/TS/TSR) is operating properly, proceed as follows. Attach a volt- meter to the terminals of the dis- pense valve solenoid. Connect the brewer to the power source. Turn on the brewer and press the BREW switch. Voltage should be present at the solenoid terminals. If voltage is not present, refer to the wiring diagrams and check the wiring har- ness. If voltage is present, check for continuity across the terminals of the solenoid coil. If continuity is not present, replace the solenoid valve (See page 26). If continuity is present, the valve may be stuck closed.

Consistently low beverage level in

1. Brew volume (CDBC-APS/TC/TS/

Set up brewer according to instruc-

the dispenser or beverage overflows

TSR & CEZ-APS/TS/TSR)

tions in section Adjustments-Brew

dispenser

NOTE: All volumes to run with

Volumes. (See pages 7 or 8) Using

 

sprayhead attached.

a stop watch or second hand, time

 

 

the length of the brew cycle. Record

 

 

this time inside the top lid. If service

 

 

is ever needed again, use the time

 

 

as reference to determine if time

 

 

has changed.

 

2. Lime build up

Inspect the dispense valve and

 

 

sprayhead for excessive lime de-

 

 

posits. Delime as required.

 

3. Dispense Valve

Remove dispense valve and clear

 

 

any obstructions. Rebuild or re-

 

 

place valve if necessary. (See page

 

 

26)