SERVICE (cont.)
TANK HEATER (Cont.)
17.Install tank assembly onto mounting brackets and secure in place with four
18.Install tank lid and secure in place with eight
19.Connect the two white wires of the tank warmer blanket.
20.Connect the limit thermostat to the front of the tank assembly.
21.Connect the green wire to the tank mounting bracket using
22.Connect the pink wire to the level probe.
23.Insert the temperature probe through the grom- met in the tank lid.
24.Install the elbow fitting of the vent hose into the grommet in the tank lid.
25.On brewers with faucet, connect the outlet water line of the faucet to the side of the tank and secure with clamp.
26.Connect the water supply tube from the solenoid to the bottom of the tank and secure with clamp.
27.Connect the water supply tube from the dispense valve to the side of the tank and secure with clamp.
28.Refer to FIG. 14 when reconnecting the tank heater wires.
29.Install access panels and covers and refer to Initial
BLK to Control Board
WHI or RED to Terminal
Block
P1856
FIG. 14 TANK HEATER WIRING
Page 30 | 29253 091603 |
|